HG/T 20519.26-1992 Equipment pipe opening orientation diagram
time:
2024-08-14 09:56:54
- HG/T 20519.26-1992
- in force
Standard ID:
HG/T 20519.26-1992
Standard Name:
Equipment pipe opening orientation diagram
Chinese Name:
设备管口方位图
Standard category:
Chemical industry standards (HG)
-
Date of Release:
1993-01-18 -
Date of Implementation:
1993-04-01
Standard ICS number:
General, Terminology, Standardization, Documentation>>Technical Drawing>>01.100.01 Technical Drawing General 71.010China Standard Classification Number:
>>>>G0 Engineering Construction>>Raw Materials Industry, Communications, Broadcasting Engineering>>P72 Petrochemical, Chemical Engineering

Skip to download
Summary:
HG/T 20519.26-1992 Equipment pipe opening orientation diagram HG/T20519.26-1992 standard download decompression password: www.bzxz.net

Some standard content:
Equipment pipe opening orientation diagram
HG 20519.26-92bZxz.net
Equipment pipe opening orientation diagram
HG20519.26-92
1 Non-standard equipment should draw a pipe opening orientation diagram, using A4 drawing sheet and simplified plane drawing. Draw a drawing for each equipment number. Equipment with the same structure but different pipe opening orientation can be drawn on the same drawing. 2 The pipe opening orientation diagram should indicate the position of the equipment's pipe opening, tank ear (hanging column), support leg (or ear seat), grounding plate, tower skirt bottom reinforcement rib and manhole on the skirt, the position and number of anchor bolt holes, and mark the pipe opening symbol (consistent with the pipe opening symbol on the equipment drawing). The anchor bolt holes on the support of horizontal equipment (including heat exchangers) must be indicated if they have different diameters or different shapes (movable end or fixed end).
3 A direction mark should be drawn in the upper right corner of the drawing. The direction indicator is in the form of a circle with a diameter of 20mm, indicating the angles of the four directions of east, west, south and north, and noting the north direction \N", such as: N
The north direction "N\" of the direction indicator should be consistent with the north direction "N" of the equipment layout drawing. 4 List the pipe opening table consistent with the equipment drawing above the title bar. Note the equipment assembly drawing number on the right side of the pipe opening table. For example: "Equipment assembly drawing number ××××××." 5 The line width of the pipe opening orientation diagram shall comply with the provisions of HG20519.28-92. 6 The following two points should be added to the equipment pipe opening orientation diagram: (1) Use paint to indicate the 0° position on the skirt or body to facilitate identification of the orientation during on-site installation. (2) Indicate the orientation and installation height of the nameplate. Indicate the thickness of the insulation layer so that the nameplate is exposed outside the insulation layer. See example figure
8-436 mid-span
equipment assembly drawing number ××××
GB 9115.10-88RFPN2.5 pressure gauge port L1.2GB9115.10-88RFPN2.5
feed port
GB9115.10-88RFPN2.5 gas outlet
GB9115.10-88RFPN2.5 temperature gauge port
nominal pipe port
symbol diameter
connection form
and standard||t t||500GB9115.10-88RFPN2.5 manhole
32GB9115.10-88RFPN2.5 liquid outlet pipe nominal
or name symbol diameter
project name:
design project:
XxXx tower
· port orientation diagram (example diagram)
connection form
or name
or name
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
HG 20519.26-92bZxz.net
Equipment pipe opening orientation diagram
HG20519.26-92
1 Non-standard equipment should draw a pipe opening orientation diagram, using A4 drawing sheet and simplified plane drawing. Draw a drawing for each equipment number. Equipment with the same structure but different pipe opening orientation can be drawn on the same drawing. 2 The pipe opening orientation diagram should indicate the position of the equipment's pipe opening, tank ear (hanging column), support leg (or ear seat), grounding plate, tower skirt bottom reinforcement rib and manhole on the skirt, the position and number of anchor bolt holes, and mark the pipe opening symbol (consistent with the pipe opening symbol on the equipment drawing). The anchor bolt holes on the support of horizontal equipment (including heat exchangers) must be indicated if they have different diameters or different shapes (movable end or fixed end).
3 A direction mark should be drawn in the upper right corner of the drawing. The direction indicator is in the form of a circle with a diameter of 20mm, indicating the angles of the four directions of east, west, south and north, and noting the north direction \N", such as: N
The north direction "N\" of the direction indicator should be consistent with the north direction "N" of the equipment layout drawing. 4 List the pipe opening table consistent with the equipment drawing above the title bar. Note the equipment assembly drawing number on the right side of the pipe opening table. For example: "Equipment assembly drawing number ××××××." 5 The line width of the pipe opening orientation diagram shall comply with the provisions of HG20519.28-92. 6 The following two points should be added to the equipment pipe opening orientation diagram: (1) Use paint to indicate the 0° position on the skirt or body to facilitate identification of the orientation during on-site installation. (2) Indicate the orientation and installation height of the nameplate. Indicate the thickness of the insulation layer so that the nameplate is exposed outside the insulation layer. See example figure
8-436 mid-span
equipment assembly drawing number ××××
GB 9115.10-88RFPN2.5 pressure gauge port L1.2GB9115.10-88RFPN2.5
feed port
GB9115.10-88RFPN2.5 gas outlet
GB9115.10-88RFPN2.5 temperature gauge port
nominal pipe port
symbol diameter
connection form
and standard||t t||500GB9115.10-88RFPN2.5 manhole
32GB9115.10-88RFPN2.5 liquid outlet pipe nominal
or name symbol diameter
project name:
design project:
XxXx tower
· port orientation diagram (example diagram)
connection form
or name
or name
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 14679-1993 Air quality-Determination of ammonia-Sodium hypochlorite-salicylic acid spectrophotometric method
- GB/T 5169.17-2002 Fire hazard tests for electrical and electronic products Part 17: 500W flame test method
- JGJ 68-1990 Code for seismic design and construction of porous brick (kp1 type) buildings JGJ68-90
- SY/T 0309-1996 Technical specification for produced water treatment in offshore petroleum projects
- GB 338-1992 Industrial methanol
- JB/T 7549.3-1994 Roller sealing machine
- GB/T 5777-1996 Ultrasonic flaw detection method for seamless steel tubes
- JB/T 7966.5-1999 Die milling cutters Part 5: Flattened straight shank conical end mills
- GB/T 11761-1989 Sesame
- GB 2731-1988 Hygienic Standard for Ham
- CB/T 3558-1994 Radiographic process and quality classification of ship steel welds
- GB 18322-2002 Free acceleration smoke emission limits and measurement methods for agricultural transport vehicles
- HG/T 2051.1-1991 Glass-lined agitator Anchor agitator
- SB/T 10517-2009 Management technical criterion for commercial streets
- GB/T 20000.1-2002 Guide for STANDARDization--Part 1:STANDARDization and related activities--General vocabulary
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com