Chemicals - Water solubility test

time: 2024-06-30 08:34:33
  • GB/T 21845-2008
  • in force

Basic Information

standard classification number

  • Standard ICS number:

    Environmental protection, health care and safety >> 13.300 Dangerous goods protection
  • China Standard Classification Number:

    Comprehensive>>Marking, packaging, transportation, storage>>A80 Marking, packaging, transportation, storage Comprehensive

associated standards

  • Procurement status:

    IDT OECD No.105:1995

Publication information

  • publishing house:

    China Standards Press
  • ISBN:

    155066·1-32501
  • Publication date:

    2008-08-01
  • Plan number:

    20075188-T-469

Other Information

  • Release date:

    2008-05-12
  • Drafter:

    Zhou Xin, Chen Huiming, Wang Junbing, Yu Wenlian, Wang Lifeng, Hao Nan, Sun Xin, Wang Zheng
  • Drafting Organization:

    China Institute of Inspection and Quarantine
  • Focal point Organization:

    National Technical Committee on Hazardous Chemicals Management Standardization
  • Proposing Organization:

    National Technical Committee on Hazardous Chemicals Management Standardization (SAC/TC 251)
  • Publishing Department:

    General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China National Standardization Administration
  • Competent Authority:

    National Standardization Administration
Introduction to standardsDescription (Translated English) / download

Skip to download

Summary:

This standard specifies the scope, definition and units, reference materials, test methods, data and reports of water solubility test of chemicals. This standard is applicable to the determination of water solubility of chemicals. GB/T 21845-2008 Water solubility test of chemicals GB/T21845-2008 Standard download decompression password: www.bzxz.net
This standard specifies the scope, definition and units, reference materials, test methods, data and reports of water solubility test of chemicals. This standard is applicable to the determination of water solubility of chemicals.
This standard is equivalent to the Organization for Economic Cooperation and Development (OECD) Chemical Testing Guide 105 (1995) "Water Solubility" (English version).
This standard has made the following editorial changes:
--- Added the scope part;
--- Changed the measurement unit to the legal measurement unit of China.
This standard is proposed and managed by the National Technical Committee for Standardization of Hazardous Chemicals Management (SAC/TC251). || tt||
The responsible drafting organization of this standard is China Institute of Inspection and Quarantine.
The main drafters of this standard are Zhou Xin, Chen Huiming, Wang Junbing, Yu Wenlian, Wang Lifeng, Hao Nan, Sun Xin and Wang Zheng.
This standard is published for the first time.
This standard is a revised version of the original OECD 105 method from 1981. There is no difference between the new version and the 1981 version in terms of chemical substances. The main format has been changed. This version is also based on the EC method "Water Solubility" [1] with some modifications.
The water solubility of a substance is greatly affected by impurities. This method is used to determine the water solubility of a pure substance that is
stable in water and not volatile. Before determining the water solubility, it is helpful to obtain some preliminary information about the compound, such as the structural formula, vapor pressure, dissociation constant and hydrolysis ability under pH conditions.
This standard introduces two methods: column elution method and flask method. In this standard, they are respectively applicable to chemicals with solubility less than and greater than 10-2g/L. This standard also introduces a simple pre-test. When the final step of the pre-test is carried out, the amount of sample used is rough, and it takes a certain amount of time for the solution to reach saturation.
Standard contentStandard content

Some standard content:

ICS13.300Www.bzxZ.net
National Standard of the People's Republic of China
GB/T 21845—2008
Chemicals
Water soluhility test
Chemicals-Water soluhility testIssued on 2008-05-12
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Administration of Standardization of the People's Republic of China
Minquer Preventive
Implementation on 2008-09-01
GB/T 21845—2008
This standard is equivalent to the Organization for Economic Cooperation and Development (OECD) Chemical Testing Guide 105 (1995) "Water Solubility" (English version). This standard has been revised as follows:
Added the scope part;
Changed the measurement unit to the legal measurement unit of my country: This standard was proposed and managed by the National Technical Committee for the Administration of Hazardous Chemicals (SAC/TC251). The responsible drafting unit of this standard: China Institute of Inspection and Quarantine. The main drafters of this standard: Zhou Xin, Chen Huiming, Wang Junbing, Yu Wenlian, Wang Lifeng, Hao Nan, Sun Xin, Yu Feng This standard is published for the first time.
http://foodmate.neGB/T218452008
OECD Introduction
This standard is a revised version of the original OECD 105 method of 1981. There is no difference between the new version and the 1981 version in terms of chemical substances. The main format has been changed. This version is also based on the EC method "Water Solubility" [1]. The water solubility of a substance is greatly affected by impurities. This method is a method for determining the water solubility of a pure substance, which must be stable and non-volatile in water. Before determining the water solubility, it is helpful to obtain some preliminary information about the compound, such as the structural formula, vapor pressure, dissociation constant and hydrolysis ability under pH conditions. This standard introduces two methods: column elution method and flask method. In this standard, they are respectively applicable to chemicals with solubility less than and greater than 10'g/L. This standard also introduces a simple preliminary test. When the preliminary test is carried out in the last step, the amount of sample used is rough, and a certain amount of time is required for the solution to reach saturation. Partner double ht
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com