JB/T 6753.5-1993 Electrical equipment - Equipment component tolerances - Assembly structure general tolerances
time:
2024-07-13 09:51:54
- JB/T 6753.5-1993
- in force
Standard ID:
JB/T 6753.5-1993
Standard Name:
Electrical equipment - Equipment component tolerances - Assembly structure general tolerances
Chinese Name:
电工设备 设备构件公差 组装结构一般公差
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1993-08-21 -
Date of Implementation:
1993-10-01
China Standard Classification Number:
Electrical Engineering>>General Electrical Engineering>>K05 Electrical Product Mechanical Structure
Focal point Organization:
Beijing Electrical Engineering Technology and Economics Research InstitutePublishing Department:
Beijing Electrical Engineering Technology and Economics Research Institute

Skip to download
Summary:
This standard specifies the general tolerances for assembly structures. This standard applies to the assembly structures of electrical equipment and the processing of the equipment components of each assembly structure. JB/T 6753.5-1993 Electrical equipment equipment component tolerances assembly structure general tolerances JB/T6753.5-1993 Standard download decompression password: www.bzxz.net

Some standard content:
Subject content and scope of application
Machinery Industry Standard of the People's Republic of China
Equipment structure tolerances of electrical equipment
General tolerances of assembled structures
This standard specifies the general tolerances of assembled structuresJB/T 6753.593
This standard applies to the assembled structures of electrical equipment and the processing of the equipment structures of each assembled structure unit2 Reference standards
JB/T6753.1 Equipment structure tolerances of electrical equipmentGeneral tolerances of sheet metal parts and structures and their selection rulesJB/T6753.4
3 Terminology
Equipment structure tolerances of electrical equipment
General tolerances of welded structures
Citing the provisions of Chapter 3 of JB/T6753.4. General tolerances
4.1 The general tolerances of height, width and depth are both A and B, and their limit deviation values are shown in Table 1. Table 1
Size segment
>120~400
>400~1000
>1000~2000
>2000~4000
The verticality tolerance of the assembled structure adopts the A or B grade of the general verticality tolerance in Table 2, Chapter 4 of JB/T6753.1. 4.2
4.3The same or parallel gaps (referring to parallel gaps with the same gap size) formed between the surface structural elements of the assembled structure (such as doors and doors; doors and other structural elements, etc.) should be uniform. The gap difference shall not exceed the value specified in Table 2. Approved by the Ministry of Machinery Industry on August 21, 1993
Implementation on October 1, 1993
≤1000
The basic size is the shorter side size of the formed gap. JB/T6753.593
4.4 The general tolerance of the flatness of panel components such as panels, side panels, door panels, etc. is 3mm per square meter. The marking
shall comply with the provisions of Chapter 9 of JB/T6753.1.
Additional remarks:
This standard is proposed and managed by the Beijing Institute of Electrical Engineering Comprehensive Technology and Economics.
This standard was drafted by Tianjin Electric Transmission Design Institute, Xuchang Relay Institute, Shenyang Low Voltage Switch Factory, and Shanghai Huatong Switch Factory. Shanghai Electric Complete Plant, Kunming Switch Factory, Beijing Second Switch Factory, and Guangzhou Nanyang Electric Factory participated in the drafting. The main drafters of this standard are Guo Xiaohu, Wang Aimian, Yin Guijun, Zhong Xiaobo, and Wang Minsheng. 12
People's Republic of China
Mechanical Industry Standard
Equipment Structure Tolerance of Electrical Equipment
JB/T6753.1~6753.5
Mechanical Standardization Research Institute of the Ministry of Machinery Industry
Edited, published and distributed by the Standardization Research Office of the First Equipment Department of the Ministry of Machinery Industry
(No. 302, Xiashesi Street, Xiangtan City, Hunan Province)bZxz.net
Printed by the Printing Plant of Xiang Electric Machinery Factory
Format 880×12301/16
First edition in April 1994
Printing number
Printing sheet 1 Number of words 30000
First printing in April 1994
1-1000
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Machinery Industry Standard of the People's Republic of China
Equipment structure tolerances of electrical equipment
General tolerances of assembled structures
This standard specifies the general tolerances of assembled structuresJB/T 6753.593
This standard applies to the assembled structures of electrical equipment and the processing of the equipment structures of each assembled structure unit2 Reference standards
JB/T6753.1 Equipment structure tolerances of electrical equipmentGeneral tolerances of sheet metal parts and structures and their selection rulesJB/T6753.4
3 Terminology
Equipment structure tolerances of electrical equipment
General tolerances of welded structures
Citing the provisions of Chapter 3 of JB/T6753.4. General tolerances
4.1 The general tolerances of height, width and depth are both A and B, and their limit deviation values are shown in Table 1. Table 1
Size segment
>120~400
>400~1000
>1000~2000
>2000~4000
The verticality tolerance of the assembled structure adopts the A or B grade of the general verticality tolerance in Table 2, Chapter 4 of JB/T6753.1. 4.2
4.3The same or parallel gaps (referring to parallel gaps with the same gap size) formed between the surface structural elements of the assembled structure (such as doors and doors; doors and other structural elements, etc.) should be uniform. The gap difference shall not exceed the value specified in Table 2. Approved by the Ministry of Machinery Industry on August 21, 1993
Implementation on October 1, 1993
≤1000
The basic size is the shorter side size of the formed gap. JB/T6753.593
4.4 The general tolerance of the flatness of panel components such as panels, side panels, door panels, etc. is 3mm per square meter. The marking
shall comply with the provisions of Chapter 9 of JB/T6753.1.
Additional remarks:
This standard is proposed and managed by the Beijing Institute of Electrical Engineering Comprehensive Technology and Economics.
This standard was drafted by Tianjin Electric Transmission Design Institute, Xuchang Relay Institute, Shenyang Low Voltage Switch Factory, and Shanghai Huatong Switch Factory. Shanghai Electric Complete Plant, Kunming Switch Factory, Beijing Second Switch Factory, and Guangzhou Nanyang Electric Factory participated in the drafting. The main drafters of this standard are Guo Xiaohu, Wang Aimian, Yin Guijun, Zhong Xiaobo, and Wang Minsheng. 12
People's Republic of China
Mechanical Industry Standard
Equipment Structure Tolerance of Electrical Equipment
JB/T6753.1~6753.5
Mechanical Standardization Research Institute of the Ministry of Machinery Industry
Edited, published and distributed by the Standardization Research Office of the First Equipment Department of the Ministry of Machinery Industry
(No. 302, Xiashesi Street, Xiangtan City, Hunan Province)bZxz.net
Printed by the Printing Plant of Xiang Electric Machinery Factory
Format 880×12301/16
First edition in April 1994
Printing number
Printing sheet 1 Number of words 30000
First printing in April 1994
1-1000
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- NY 5255-2004 Non-polluting food dragon fruit
- SY/T 5379-1991 Technical requirements for drilling fluid shear force gauges
- QB/T 2399-1998 Watch crown and crown tube matching size series
- JB 8432.1-1996 On-site mixing and loading of heavy ammonium oil explosives truck
- CB/T 3558-1994 Radiographic process and quality classification of ship steel welds
- GB/T 3048.2-1994 Test methods for electrical properties of wires and cables - Test method for resistivity of metallic conductor materials
- JB/T 6521-1992 General technical requirements for industrial boiler coal loading machines
- QX/T 211-2019 Technical specifications for inspection of lightning protection system on expressway facilities
- JB/T 5300-1991 General valve materials
- GB/T 325.1-2008 Packing containers - Steel drums - Part 1:General specifications
- SJ 20732-1999 General specification for mobile communication RF power amplifier
- GB/T 585-1999 Marine flange cast steel stop check valve
- SY/T 5345-1999 Determination of oil-water relative permeability
- JB/T 10231.2-2001 Tool product testing methods Part 1: Twist drills
- JB/T 10451-2004 Special requirements for multi-user static AC active energy meters
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com