标准下载网/IEC 60909-2 Short-circuit currents in three phase

IEC 60909-2 Short-circuit currents in three phase

三相交流系统中的短路电流 - 第2部分:用于短路电流计算的电气设备数据

IEC 60909-2 Short-circuit currents in three phase a.c. systems-2 Data of electrical equipment for short-circuit current calculations

Short-circuit currents in three-phase a.c. systems – Part 2: Data of electrical equipment for short-circuit current calculations

版本年份 2008 文件语言 英语 全文 6 页 格式 PDF
IEC 60909-2 Short-circuit currents in three phase 三相交流系统中的短路电流 - 第2部分:用于短路电流计算的电气设备数据封面

标准信息

STANDARD INFORMATION
标准编号
IEC 60909-2 Short-circuit currents in three phase
所属分类
IEC 国际电工标准
发布机构
IEC
版本年份
2008
文件语言
英语
文件格式
PDF
文件页数
6 页
文件大小
6.05 MB

中文名称为参考译名,文件语言以原文为准。

· 更新:

标准简介

OVERVIEW

中文简介

该标准提供了用于计算三相交流系统中短路电流的电气设备典型数据,包括同步电机、变压器、架空线、电缆和异步电机等。这些数据适用于在缺乏制造商具体参数时,进行低压、中压或高压网络的短路电流计算及规划。

English summary

This standard provides typical data for electrical equipment, such as synchronous machines, transformers, overhead lines, cables, and asynchronous motors, used for calculating short-circuit currents in three-phase a.c. systems. It is applicable for low-, medium-, and high-voltage network planning and calculations when specific manufacturer data is unavailable.

以上为根据文件整理的内容简介。

相关标签

标准内容预览

DOCUMENT PREVIEW
点击页码切换内容
IEC 60909-2 Short-circuit currents in three phasePDF 第 1 页 · 原页码 1

SHORT-CIRCUIT CURRENTS IN THREE-PHASE AC SYSTEMS – Part 2: Data of electrical equipment for short-circuit current calculations

1 General

1.1 Scope and object

This part of IEC 60909 comprises data of electrical equipment collected from different countries to be used when necessary for the calculation of short-circuit currents in accordance with IEC 60909-0.

Generally, electrical equipment data are given by the manufacturers on the name plate or by the electricity supplier.

In some cases, however, the data may not be available. The data in this report may be applied for calculating short-circuit currents in low-voltage networks if they are in accordance with typical equipment employed in the user's country. The collected data and their evaluation may be used for medium- or high-voltage planning purposes and also for comparison with data given by manufacturers or electricity suppliers. For overhead lines and cables the electrical data may in some cases also be calculated from the physical dimensions and the material following the equations given in this report.

Thus this technical report is an addition to IEC 60909-0. It does not, however, change the basis for the standardized calculation procedure given in IEC 60909-0 and IEC 60909-3.

1.2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

IEC 60909-0:2001, Short-circuit currents in three-phase a.c. systems – Part 0: Calculation of currents

IEC 60909-3:-1, Short-circuit currents in three-phase a.c. systems – Part 3: Currents during two separate simultaneous line-to-earth short-circuit currents and partial short-circuit currents flowing through earth

2 Data for electrical equipment

2.1 General

The data presented are necessary for the calculation of short-circuit currents. They are sometimes presented in the form of curve sheets and sometimes in the form of examples in tables. In the case of easy equations they are given for the calculations of positive-sequence and zero-sequence short-circuit impedances for overhead lines and cables.

1 To be published.

In all, 15 National Committees provided information in response to a questionnaire sent out before the first edition of this report. Table 1 of the first edition of this report is given in Annex A.

In some cases, average values or characteristic trends as function of rated power, rated voltage, etc. are given.

2.2 Data of typical synchronous machines

Characteristic data of synchronous machines are listed in Table 1. The reactances are given as relative values related to ZRG = URG2/SRG (see IEC 60909-0). Sometimes they are given in %.

In Figure 1 the sub-transient reactances of synchronous machines (generators, motors and condensers) in the direct axis of 50 Hz or 60 Hz machines are plotted as a function of the rated power.

Table 1 – Actual data of typical synchronous generators, motors and condensers
No Type a) Rated appar. power Rated voltage and deviation b) Power factor Relative values of reactances and d.c. time constant Note National Committee
SRG URG ±PG cos φRG xd* xd(2) c) xd(0) d) xd e) xdsat f) TDC g)
- MVA kV % - - - - - - - s
1TG26413,8±50,850,1790,1700,1041,871,870,22060 HzUSA
2TG210010,5±50,800,134--1,771,450,24650 HzGermany
3TG212510,5±50,800,1600,1800,082,131,870,46050 Hzex-GDR
4TG218010,5±50,900,2500,2300,141,831,770,48050 HzAustria
5TG235318,0±50,850,1670,2040,0892,262,170,19450 HzChina
6TG2388,917,5±50,900,2030,2020,0992,422,190,25050 HzAustralia
7SG144810±50,900,160,170,050,78-0,1650 HzItaly
8SG2029018,0±50,900,220,220,141,030,960,3660 HzJapan
9SM21,4510+50,900,1660,1660,0461,63-0,0450 Hzex-USSR
10SM33,404,0±50,800,2490,303-2,6752,6750,11660 HzUSA
11SC104013,8±500,1190,129-1,331,330,142560 HzUSA
12SC610010,5±500,200,250,0951,781,600,5750 Hzex-Czechoslovakia

a) TG2: Two-pole turbo generator

SG: Salient pole generator

SM: Synchronous motor

SC: Salient pole synchronous condenser

b) UG = URG(1 ± PG/100%)

c) Negative-sequence reactance

d) Zero-sequence reactance

e) Unsaturated synchronous reactance

f) Saturated synchronous reactance

g) DC time constant for a three-phase terminal short circuit

6