Chapter 3 - Short circuit current calc
三相系统中短路电流的计算
Chapter 3 - Short circuit current calc
Calculation of Short-Circuit Currents in Three-Phase Systems
标准信息
STANDARD INFORMATION- 标准编号
- Chapter 3 - Short circuit current calc
- 所属分类
- 其他国外标准与工程资料
- 发布机构
- DIN
- 版本年份
- 1997
- 文件语言
- 英语
- 文件格式
- 文件页数
- 6 页
- 文件大小
- 626.44 KB
中文名称为参考译名,文件语言以原文为准。
· 更新:
标准简介
OVERVIEW中文简介
该标准规定了三相交流系统中短路电流和短路功率的计算方法。内容涵盖了对称与非对称故障的定义、正序/负序/零序阻抗分析,以及基于DIN VDE 0102/IEC 909标准的初始对称短路电流和峰值短路电流的计算公式。适用于电气网络设备的选型及特性确定,涵盖低压、中压和高压系统。
English summary
This standard specifies the calculation methods for short-circuit currents and powers in three-phase AC systems. It covers definitions of symmetrical and asymmetrical faults, sequence impedance analysis, and formulas for calculating initial symmetrical and peak short-circuit currents based on DIN VDE 0102/IEC 909. It applies to the selection and determination of characteristics for electrical network equipment in low, medium, and high-voltage systems.
以上为根据文件整理的内容简介。
相关标签
标准内容预览
DOCUMENT PREVIEWCalculation of peak short-circuit current ip
When calculating the peak short-circuit current ip, sequential faults are disregarded. Three-phase short circuits are treated as though the short circuit occurs in all three conductors simultaneously. We have:
ip = κ · √2 · Ik"
The factor κ takes into account the decay of the d. c. component. It can be calculated as
κ = 1.02 + 0.98 e-3 R/X or taken from Fig. 3-2.
Exact calculation of ip with factor κ is possible only in networks with branches having the same ratios R/X. If a network includes parallel branches with widely different ratios R/X, the following methods of approximation can be applied:
a) Factor κ is determined uniformly for the smallest ratio R/X. One need only consider the branches which are contained in the faulted network and carry partial short-circuit currents.
b) The factor is found for the ratio R/X from the resulting system impedance Zk = Rk + jXk at the fault location, using 1.15 · κk for calculating ip. In low-voltage networks the product 1.15 · κ is limited to 1.8, and in high-voltage networks to 2.0.
c) Factor κ can also be calculated by the method of the equivalent frequency as in IEC 909 para. 9.1.3.2.
The maximum value of κ = 2 is attained only in the theoretical limiting case with an active resistance of R = 0 in the short-circuit path. Experience shows that with a short-circuit at the generator terminals a value of κ = 1.8 is not exceeded with machines < 100 MVA.
With a unit-connected generator and high-power transformer, however, a value of κ = 1.9 can be reached in unfavourable circumstances in the event of a short circuit near the transformer on its high-voltage side, owing to the transformer's very small ratio R/X. The same applies to networks with a high fault power if a short circuit occurs after a reactor.
6
2 Scope
2
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM
EN 10216-3
May 2002
ICS 23.040.10; 77.140.75
English version
Seamless steel tubes for pressure purposes –
Technical delivery conditions
Part 3: Alloy fine grain steel tubes
Tubes sans soudure en acier pour service sous pression – Conditions techniques de livraison – Partie 3: Tubes en acier allié à grain fin
Nahtlose Stahlrohre für Druckbeanspruchungen – Technische Lieferbedingungen – Teil 3: Rohre aus legierten Feinkornbaustählen
This European Standard was approved by CEN on 2002-04-25.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Management Centre or to any CEN member.
The European Standards exist in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, the Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, the Netherlands, Norway, Portugal, Spain, Sweden, Switzerland, and the United Kingdom.
CEN
European Committee for Standardization
Comité Européen de Normalisation
Europäisches Komitee für Normung
Management Centre: rue de Stassart 36, B-1050 Brussels
© 2002. CEN – All rights of exploitation in any form and by any means reserved worldwide for CEN national members.
Ref. No. EN 10216-3 : 2002 E
Contents
| Section | Page |
|---|---|
| Foreword | 3 |
| Introduction | 4 |
| 1 Scope | 4 |
| 2 Normative references | 5 |
| 3 Definitions | 5 |
| 3.1 DN | 5 |
| 3.2 PN | 5 |
| 4 Designations | 6 |
| 4.1 Range of PN designations | 6 |
| 4.2 Range of DN (nominal sizes) | 6 |
| 4.3 Gasket types | 6 |
| 4.4 Information to be supplied by the purchaser | 6 |
| 5 Gasket designs | 6 |
| 6 Gasket types | 7 |
| 7 Dimensions | 7 |
| 8 Marking | 10 |
| Annex A (informative) Information to be supplied by the purchaser | 10 |
| Annex B (informative) A-deviation | 11 |
:current
Foreword
This document (EN 10216-3:2002) has been prepared by Technical Committee EC/TC 29, "Steel tubes and fittings for steel tubes", the secretariat of which is held by UNI.
This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by November 2002, and conflicting national standards shall be withdrawn at the latest by November 2002.
This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative annex ZA, which is an integral part of this document.
Other Parts of EN 10216 are:
| Part 1: | Non-alloy steel tubes with specified room temperature properties |
| Part 2: | Non-alloy and alloy steel tubes with specified elevated temperature properties |
| Part 4: | Non-alloy and alloy steel tubes with specified low temperature properties |
| Part 5: | Stainless steel tubes |
Another European Standard series covering tubes for pressure purposes is:
| EN 10217: | Welded steel tubes for pressure purposes |
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom.
5
1 Scope
This Part of EN 10216 specifies the technical delivery conditions in two test categories for seamless tubes of circular cross section, made of weldable alloyed fine grained steel.
2 Normative references
This European Standard incorporates by date or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For date references, subsequent amendments to or revisions of, any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies (including amendments).
The requirements of this European Standard rule when they differ from those in the standards and documents referred to below:
EN 10002-1, Metallic materials - Tensile testing - Part 1: Method of test (at ambient temperature).
EN 10002-5, Metallic materials - Tensile testing - Part 5: Method of testing (at elevated temperature).
EN 10020, Definitions and classification of grades of steel.
EN 10021, General technical delivery requirements for steel and iron products.
EN 10045-1, Metallic materials - Charpy impact test - Part 1: Test method.
EN 10052, Vocabulary of heat treatment terms for ferrous products.
EN 10204, Metallic products - Types of inspection documents.
EN 10027-1, Designation systems for steels - Part 1: Steel names, principle symbols.
EN 10027-2, Designation systems for steels Part 2: Numerical systems.
ENV 10220, Seamless and welded steel tubes - Dimensions and masses per unit length
EN 10233, Metallic materials - Tubes - Flattening test.
EN 10234, Metallic materials - Tubes - Drift expanding test.
EN 10236, Metallic materials - Tubes - Ring expanding test.
EN 10237, Metallic materials - Tubes - Ring tensile test.
EN 10246-1, Non-Destructive Testing of steel tubes Part 1: Automatic electromagnetic testing of seamless and welded (except submerged arc welded) ferromagnetic steel tubes for verification of hydraulic leak-tightness.
EN 10246-5, Non-Destructive Testing of steel tubes - Part 5: Automatic full peripheral magnetic transducer/flux leakage testing of seamless and welded (except submerged arc-welded) ferromagnetic steel tubes for the detection of longitudinal imperfections.
EN 10246-6, Non-Destructive Testing of steel tubes - Part 6: Automatic full peripheral ultrasonic testing of seamless steel tubes for the detection of transverse imperfections.
EN 10246-7, Non-Destructive Testing of steel tubes - Part 7: Automatic full peripheral ultrasonic testing of seamless and welded (except submerged arc welded) steel tubes for the detection of longitudinal imperfections.
6
预览内容由文件识别整理,表格、公式及文字请以原始文件为准。
原文图片预览
PAGE IMAGES下载标准文件
Chapter 3 - Short circuit current calc
英语 · PDF · 6 页 · 626.44 KB