该标准规定了用于对焊连接的无缝和焊接偏心钢制异径管的尺寸、标记及压力系数。它详细列出了不同公称直径(DN)和壁厚系列下的几何参数,并明确了由于偏心结构导致的压力降低系数,适用于管道系统中的变径连接。
English summary
This standard specifies the dimensions, designation, and pressure factors for seamless and welded eccentric steel reducers intended for butt welding to pipes. It details geometric parameters for various nominal diameters (DN) and wall thickness series, defining the reduced pressure factor applicable to eccentric reducers in piping systems.
以上为根据文件整理的内容简介。
相关标签
标准内容预览
DOCUMENT PREVIEWSteel butt-welding pipe fittings
Eccentric reducers with reduced pressure factor
Formstücke zum Einschweißen; Reduzierstücke;
verminderter Ausnutzungsgrad
This standard, together with
February 1991 edition of DIN 2616 Part 2,
supersedes June 1964 edition of DIN 2616.
In keeping with current practice in standards published by the International Organization for Standardization (ISO), a comma has been used throughout as the decimal marker.
Dimensions in mm
1 Field of application
This standard specifies seamless and welded eccentric steel reducers that are intended to be butt welded to pipes. Although the wall thicknesses specified correspond to those of the pipes, these reducers do not permit operation at the same internal pressure as the pipe welded to the larger end of the reducer, i.e. they have a reduced pressure factor (cf. table 2 and clause 4). See DIN 2616 Part 2 for specifications regarding concentric reducers.
2 Dimensions and designation
Detail X
Detail Y
Dimensions a, l2 and l3 are to be calculated from the following formulae.
a = (d1 − d2) / 2
l2 min = 0,5 · d1 · s1
l3 min = 0,5 · d2 · s2
Figure 1. Eccentric reducer
Designation of a seamless (S), eccentric (E) reducer in accordance with this standard (1), where d1 is equal to 114,3 mm, s1 is equal to 3,6 mm, d2 is equal to 60,3 mm and s2 is equal to 2,9 mm, made from material belonging to material group G as in DIN 2609 (G):
Reducer DIN 2616 − 1 − E − 114,3 × 3,6 − 60,3 × 2,9 S − G
| Nominal size DN | Minimum radius, r |
|---|---|
| 15 to 50 | 20 |
| 65 to 300 | 30 |
| 350 to 600 | 100 |
| 700 or more | 120 |
Continued on pages 2 to 7
1
Table 2 - Dimensions and pressure factor as a function of size
| Nominal size DN1 | Wall thickness, s1, for series | αmax° | Nominal size DN2 | Diameter, d2 | Wall thickness, s2, for series | l1 | Maximum pressure factor, as a percentage, for series | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 5 | 1 | 2 | 3 | 4 | 5 | 1 | 2 | 3 | 4 | 5 | |||||
| 15 | 21,3 | 1,6 | — | 2,0 | 3,2 | 4,0 | 10 | 17,2 | 1,6 | — | 1,8 | 2,9 | — | 38 | 97 | — | 95 | 91 | — |
| 20 | 26,9 | 1,6 | — | 2,3 | 3,2 | 4,0 | 15 | 21,3 | 1,6 | — | 2,0 | 3,2 | 4,0 | 38 | 99 | — | 98 | 96 | 100 |
| 10 | 17,2 | 1,6 | — | 1,8 | 2,9 | — | 100 | — | 100 | 100 | — | ||||||||
| 25 | 33,7 | 2,0 | — | 2,6 | 3,2 | 4,0 | 20 | 26,9 | 1,6 | — | 2,3 | 3,2 | 4,0 | 50 | 98 | — | 97 | 96 | 100 |
| 15 | 21,3 | 1,6 | — | 2,0 | 3,2 | 4,0 | 100 | — | 100 | 100 | 100 | ||||||||
| 32 | 42,4 | 2,0 | — | 2,6 | 3,6 | 4,0 | 25 | 33,7 | 2,0 | — | 2,6 | 3,2 | 4,0 | 50 | 99 | — | 99 | 97 | 100 |
| 20 | 26,9 | 1,6 | — | 2,3 | 3,2 | 4,0 | 100 | — | 100 | 100 | 100 | ||||||||
| 40 | 48,3 | 2,0 | — | 2,6 | 4,0 | 5,0 | 32 | 42,4 | 2,0 | — | 2,6 | 3,6 | 4,0 | 64 | 98 | — | 97 | 95 | 100 |
| 25 | 33,7 | 2,0 | — | 2,6 | 3,2 | 4,0 | 99 | — | 99 | 98 | 100 | ||||||||
| 50 | 60,3 | 2,0 | — | 2,9 | 4,5 | 5,6 | 40 | 48,3 | 2,0 | — | 2,6 | 4,0 | 5,0 | 76 | 99 | — | 98 | 97 | 100 |
| 32 | 42,4 | 2,0 | — | 2,6 | 3,6 | 4,0 | 99 | — | 99 | 98 | 100 | ||||||||
| 65 | 76,1 | 2,3 | — | 2,9 | 5,0 | 7,1 | 50 | 60,3 | 2,0 | — | 2,9 | 4,5 | 5,6 | 90 | 95 | — | 96 | 98 | 100 |
| 40 | 48,3 | 2,0 | — | 2,6 | 4,0 | 5,0 | 98 | — | 99 | 99 | 100 | ||||||||
| 80 | 88,9 | 2,3 | — | 3,2 | 5,6 | 8,0 | 32 | 42,4 | 2,0 | — | 2,6 | 3,6 | 4,0 | 90 | 96 | — | 97 | 99 | 100 |
| 25 | 33,7 | 2,0 | — | 2,6 | 3,2 | 4,0 | 93 | — | 94 | 97 | 100 | ||||||||
| 65 | 76,1 | 2,3 | — | 2,9 | 5,0 | 7,1 | 90 | 99 | — | 99 | 97 | 100 | |||||||
| 50 | 60,3 | 2,0 | — | 2,9 | 4,5 | 5,6 | 92 | — | 97 | 98 | 100 | ||||||||
| 40 | 48,3 | 2,0 | — | 2,6 | 4,0 | 5,0 | 90 | 89 | — | 90 | 94 | 100 | |||||||
| 32 | 42,4 | 2,0 | — | 2,6 | 3,6 | 4,0 | 83 | — | 85 | 90 | 98 | ||||||||
A dash in a box indicates a size that has not been standardized.
2
Table 2 (continued).
| Nominal size DN1 | Diameter, d1 | Wall thickness, s1, for series | α < α° max. | Nominal size DN2 | Diameter, d2 | Wall thickness, s2, for series | l1 | Maximum pressure factor, as a percentage, for series | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 5 | 1 | 2 | 3 | 4 | 5 | 1 | 2 | 3 | 4 | 5 | ||||||
| 100 | 114,3 | 2,6 | — | 3,6 | 6,3 | 8,8 | 24 | 80 | 88,9 | 2,3 | — | 3,2 | 5,6 | 8,0 | 100 | 97 | — | 98 | 98 | 100 |
| 37 | 65 | 76,1 | 2,3 | — | 2,9 | 5,0 | 7,1 | 91 | — | 92 | 94 | 99 | ||||||||
| 51 | 50 | 60,3 | 2,0 | — | 2,9 | 4,5 | 5,6 | 79 | — | 80 | 84 | 94 | ||||||||
| 60 | 40 | 48,3 | 2,0 | — | 2,6 | 4,0 | 5,0 | 67 | — | 69 | 74 | 87 | ||||||||
| 125 | 139,7 | 2,6 | — | 4,0 | 6,3 | 10,0 | 18 | 100 | 114,3 | 2,6 | — | 3,6 | 6,3 | 8,8 | 127 | 98 | — | 98 | 98 | 100 |
| 35 | 80 | 88,9 | 2,3 | — | 3,2 | 5,6 | 8,0 | 91 | — | 92 | 94 | 97 | ||||||||
| 43 | 65 | 76,1 | 2,3 | — | 2,9 | 5,0 | 7,1 | 85 | — | 86 | 88 | 88 | ||||||||
| 51 | 50 | 60,3 | 2,0 | — | 2,9 | 4,5 | 5,6 | 76 | — | 78 | 81 | 83 | ||||||||
| 150 | 168,3 | 2,6 | 4,0 | 4,5 | 7,1 | 11,0 | 18 | 125 | 139,7 | 2,6 | 4,0 | 4,0 | 6,3 | 10,0 | 140 | 98 | 98 | 98 | 98 | 100 |
| 34 | 100 | 114,3 | 2,6 | 3,6 | 3,6 | 6,3 | 8,8 | 91 | 92 | 92 | 92 | 97 | ||||||||
| 48 | 80 | 88,9 | 2,3 | 3,2 | 3,2 | 5,6 | 8,0 | 78 | 79 | 80 | 82 | 88 | ||||||||
| 52 | 65 | 76,1 | 2,3 | 2,9 | 2,9 | 5,0 | 7,1 | 73 | 75 | 75 | 78 | 83 | ||||||||
| 200 | 219,1 | 2,9 | 4,5 | 6,3 | 8,0 | 12,5 | 31 | 150 | 168,3 | 2,6 | 4,0 | 4,5 | 7,1 | 11,0 | 152 | 92 | 92 | 93 | 94 | 97 |
| 45 | 125 | 139,7 | 2,6 | 4,0 | 4,0 | 6,3 | 10,0 | 79 | 81 | 82 | 83 | 88 | ||||||||
| 55 | 100 | 114,3 | 2,6 | 3,6 | 3,6 | 6,3 | 8,8 | 67 | 68 | 70 | 71 | 76 | ||||||||
| 61 | 80 | 88,9 | 2,3 | 3,2 | 3,2 | 5,6 | 8,0 | 58 | 59 | 61 | 62 | 67 | ||||||||
| 250 | 273,0 | 2,9 | 5,0 | 6,3 | 8,8 | 14,2 | 28 | 200 | 219,1 | 2,9 | 4,5 | 6,3 | 8,0 | 12,5 | 178 | 93 | 94 | 94 | 95 | 97 |
| 48 | 150 | 168,3 | 2,6 | 4,0 | 4,5 | 7,1 | 11,0 | 75 | 76 | 77 | 79 | 83 | ||||||||
| 55 | 125 | 139,7 | 2,6 | 4,0 | 4,0 | 6,3 | 10,0 | 65 | 67 | 68 | 70 | 74 | ||||||||
| 60 | 100 | 114,3 | 2,6 | 3,6 | 3,6 | 6,3 | 8,8 | 58 | 59 | 60 | 62 | 66 | ||||||||
| 300 | 323,9 | 2,9 | 5,6 | 7,1 | 10,0 | 16,0 | 23 | 250 | 273,0 | 2,9 | 5,0 | 6,3 | 8,8 | 14,2 | 203 | 95 | 96 | 96 | 96 | 98 |
| 44 | 200 | 219,1 | 2,9 | 4,5 | 6,3 | 8,0 | 12,5 | 78 | 80 | 81 | 82 | 86 | ||||||||
| 55 | 150 | 168,3 | 2,6 | 4,0 | 4,5 | 7,1 | 11,0 | 64 | 66 | 67 | 70 | 73 | ||||||||
| 60 | 125 | 139,7 | 2,6 | 4,0 | 4,0 | 6,3 | 10,0 | 57 | 59 | 60 | 61 | 65 | ||||||||
A dash in a box indicates a size that has not been standardized.
3
Table 2 (continued).
| Nominal size DN1 | Wall thickness, s1, for series | Diameter, d1 | α1o max. | Nominal size DN2 | Diameter, d2 | Wall thickness, s2, for series | l1 | Maximum pressure factor, as a percentage, for series | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 5 | 1 | 2 | 3 | 4 | 5 | 1 | 2 | 3 | 4 | 5 | ||||||
| 350 | 3,2 | 5,6 | 8,0 | 11,0 | 17,5 | 355,6 | 8 | 300 | 323,9 | 2,9 | 5,6 | 7,1 | 10,0 | 16,0 | 330 | 99 | 99 | 99 | 98 | 99 |
| 25 | 250 | 273,0 | 2,9 | 5,0 | 6,3 | 8,8 | 14,2 | 96 | 97 | 97 | 97 | 100 | ||||||||
| 37 | 200 | 219,1 | 2,9 | 4,5 | 6,3 | 8,0 | 12,5 | 89 | 90 | 91 | 93 | 96 | ||||||||
| 47 | 150 | 168,3 | 2,6 | 4,0 | 4,5 | 7,1 | 11,0 | 80 | 82 | 83 | 85 | 90 | ||||||||
| 15 | 350 | 355,6 | 3,2 | 5,6 | 8,0 | 11,0 | 17,5 | 99 | 99 | 99 | 99 | 100 | ||||||||
| 400 | 3,2 | 6,3 | 8,8 | 12,5 | 20,0 | 406,4 | 24 | 300 | 323,9 | 2,9 | 5,6 | 7,1 | 10,0 | 16,0 | 355 | 96 | 97 | 97 | 97 | 100 |
| 36 | 250 | 273,0 | 2,9 | 5,0 | 6,3 | 8,8 | 14,2 | 89 | 90 | 91 | 92 | 96 | ||||||||
| 46 | 200 | 219,1 | 2,9 | 4,5 | 6,3 | 8,0 | 12,5 | 80 | 82 | 83 | 85 | 89 | ||||||||
| 55 | 150 | 168,3 | 2,6 | 4,0 | 4,5 | 7,1 | 11,0 | 69 | 71 | 73 | 75 | 80 | ||||||||
| 11 | 400 | 406,4 | 3,2 | 6,3 | 8,8 | 12,5 | 20,0 | 99 | 99 | 99 | 98 | 99 | ||||||||
| 450 | 4,0 | 6,3 | 10,0 | 14,2 | 22,2 | 457,0 | 24 | 350 | 355,6 | 3,2 | 5,6 | 8,0 | 11,0 | 17,5 | 381 | 96 | 96 | 97 | 97 | 99 |
| 31 | 300 | 323,9 | 2,9 | 5,6 | 7,1 | 10,0 | 16,0 | 92 | 93 | 94 | 95 | 97 | ||||||||
| 41 | 250 | 273,0 | 2,9 | 5,0 | 6,3 | 8,8 | 14,2 | 84 | 85 | 87 | 88 | 92 | ||||||||
| 50 | 200 | 219,1 | 2,9 | 4,5 | 6,3 | 8,0 | 12,5 | 75 | 76 | 78 | 80 | 84 | ||||||||
| 8 | 450 | 457,0 | 4,0 | 6,3 | 10,0 | 14,2 | 22,2 | 99 | 99 | 99 | 98 | 99 | ||||||||
| 500 | 4,0 | 6,3 | 11,0 | 16,0 | 25,0 | 508,0 | 18 | 400 | 406,4 | 3,2 | 6,3 | 8,8 | 12,5 | 20,0 | 508 | 98 | 98 | 98 | 98 | 100 |
| 27 | 350 | 355,6 | 3,2 | 5,6 | 8,0 | 11,0 | 17,5 | 94 | 94 | 95 | 96 | 98 | ||||||||
| 32 | 300 | 323,9 | 2,9 | 5,6 | 7,1 | 10,0 | 16,0 | 91 | 92 | 93 | 94 | 97 | ||||||||
| 40 | 250 | 273,0 | 2,9 | 5,0 | 6,3 | 8,8 | 14,2 | 85 | 86 | 87 | 89 | 92 | ||||||||
| 46 | 200 | 219,1 | 2,9 | 4,5 | 6,3 | 8,0 | 12,5 | 78 | 80 | 82 | 83 | 87 | ||||||||
4
Table 2 (continued).
| Nominal size DN1 | Diameter, d1 | Wall thickness, s1, for series | αmax ° | Nominal size DN2 | Diameter, d2 | Wall thickness, s2, for series | l1 | Maximum pressure factor, as a percentage, for series | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 5 | 1 | 2 | 3 | 4 | 5 | 1 | 2 | 3 | 4 | 5 | ||||||
| 600 | 610,0 | 5,0 | 6,3 | 12,5 | 17,5 | 30,0 | 17 | 500 | 508,0 | 4,0 | 6,3 | 11,0 | 16,0 | 25,0 | 508 | 98 | 98 | 98 | 98 | 98 |
| 27 | 450 | 457,0 | 4,0 | 6,3 | 10,0 | 14,2 | 22,2 | 94 | 94 | 95 | 95 | 97 | ||||||||
| 35 | 400 | 406,4 | 3,2 | 6,3 | 8,8 | 12,5 | 20,0 | 88 | 89 | 90 | 91 | 93 | ||||||||
| 42 | 350 | 355,6 | 3,2 | 5,6 | 8,0 | 11,0 | 17,5 | 82 | 82 | 84 | 86 | 89 | ||||||||
| 46 | 300 | 323,9 | 2,9 | 5,6 | 7,1 | 10,0 | 16,0 | 78 | 78 | 80 | 82 | 85 | ||||||||
| 51 | 250 | 273,0 | 2,9 | 5,0 | 6,3 | 8,8 | 14,2 | 72 | 72 | 75 | 76 | 80 | ||||||||
| 700 | 711,0 | 5,0 | 7,1 | 12,5 | 20,0 | 32,0 | 19 | 600 | 610,0 | 5,0 | 6,3 | 12,5 | 17,5 | 30,0 | 610 | 97 | 97 | 98 | 98 | 98 |
| 34 | 500 | 508,0 | 4,0 | 6,3 | 11,0 | 16,0 | 25,0 | 89 | 89 | 91 | 92 | 94 | ||||||||
| 40 | 450 | 457,0 | 4,0 | 6,3 | 10,0 | 14,2 | 22,2 | 84 | 84 | 86 | 87 | 90 | ||||||||
| 45 | 400 | 406,4 | 3,2 | 6,3 | 8,8 | 12,5 | 20,0 | 79 | 79 | 81 | 83 | 86 | ||||||||
| 50 | 350 | 355,6 | 3,2 | 5,6 | 8,0 | 11,0 | 17,5 | 73 | 74 | 75 | 77 | 80 | ||||||||
| 52 | 300 | 323,9 | 2,9 | 5,6 | 7,1 | 10,0 | 16,0 | 70 | 71 | 73 | 75 | 78 | ||||||||
| 800 | 813,0 | 5,6 | 8,0 | 12,5 | 22,2 | 36,0 | 19 | 700 | 711,0 | 5,0 | 7,1 | 12,5 | 20,0 | 32,0 | 610 | 97 | 97 | 97 | 98 | 98 |
| 34 | 600 | 610,0 | 5,0 | 6,3 | 12,5 | 17,5 | 30,0 | 88 | 89 | 90 | 91 | 93 | ||||||||
| 45 | 500 | 508,0 | 4,0 | 6,3 | 11,0 | 16,0 | 25,0 | 78 | 79 | 80 | 82 | 85 | ||||||||
| 50 | 450 | 457,0 | 4,0 | 6,3 | 10,0 | 14,2 | 22,2 | 72 | 73 | 74 | 77 | 80 | ||||||||
| 53 | 400 | 406,4 | 3,2 | 6,3 | 8,8 | 12,5 | 20,0 | 68 | 69 | 70 | 73 | 76 | ||||||||
| 57 | 350 | 355,6 | 3,2 | 5,6 | 8,0 | 11,0 | 17,5 | 62 | 63 | 65 | 67 | 70 | ||||||||
| 900 | 914,0 | 6,3 | 10,0 | 12,5 | 25,0 | 40,0 | 19 | 800 | 813,0 | 5,6 | 8,0 | 12,5 | 22,2 | 36,0 | 610 | 97 | 97 | 97 | 98 | 98 |
| 34 | 700 | 711,0 | 5,0 | 7,1 | 12,5 | 20,0 | 32,0 | 88 | 89 | 89 | 91 | 93 | ||||||||
| 45 | 600 | 610,0 | 5,0 | 6,3 | 12,5 | 17,5 | 30,0 | 78 | 79 | 79 | 82 | 84 | ||||||||
| 53 | 500 | 508,0 | 4,0 | 6,3 | 11,0 | 16,0 | 25,0 | 68 | 69 | 69 | 72 | 75 | ||||||||
| 56 | 450 | 457,0 | 4,0 | 6,3 | 10,0 | 14,2 | 22,2 | 63 | 65 | 65 | 68 | 71 | ||||||||
| 59 | 400 | 406,4 | 3,2 | 6,3 | 8,8 | 12,5 | 20,0 | 59 | 60 | 61 | 63 | 67 | ||||||||
5
Table 2 (concluded)
| Nominal size DN1 | Diameter, d1 | Wall thickness, s1, for series | αmax ° | Nominal size DN2 | Diameter, d2 | Wall thickness, s2, for series | l1 | Maximum pressure factor, as a percentage, for series | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 5 | 1 | 2 | 3 | 4 | 5 | 1 | 2 | 3 | 4 | 5 | ||||||
| 1000 | 1016,0 | 6,3 | 10,0 | 12,5 | 28,0 | 45,0 | 19 | 900 | 914,0 | 6,3 | 10,0 | 12,5 | 25,0 | 40,0 | 610 | 97 | 97 | 97 | 98 | 98 |
| 34 | 800 | 813,0 | 5,6 | 8,0 | 12,5 | 22,2 | 36,0 | 88 | 88 | 89 | 91 | 92 | ||||||||
| 45 | 700 | 711,0 | 5,0 | 7,1 | 12,5 | 20,0 | 32,0 | 77 | 78 | 79 | 81 | 84 | ||||||||
| 54 | 600 | 610,0 | 5,0 | 6,3 | 12,5 | 17,5 | 30,0 | 66 | 67 | 67 | 70 | 73 | ||||||||
| 61 | 500 | 508,0 | 4,0 | 6,3 | 11,0 | 16,0 | 25,0 | 55 | 56 | 57 | 60 | 63 | ||||||||
| 64 | 450 | 457,0 | 4,0 | 6,3 | 10,0 | 14,2 | 22,2 | 50 | 51 | 52 | 55 | 58 | ||||||||
| 30 | 1000 | 1016,0 | 6,3 | 10,0 | - | - | - | 711 | 90 | 91 | - | - | - | |||||||
| 1200 | 1220,0 | 6,3 | 12,5 | - | - | - | 41 | 900 | 914,0 | 6,3 | 10,0 | - | - | - | 81 | 82 | - | - | - | |
| 49 | 800 | 813,0 | 5,6 | 8,0 | - | - | - | 71 | 73 | - | - | - | ||||||||
| 55 | 700 | 711,0 | 5,0 | 7,1 | - | - | - | 63 | 65 | - | - | - | ||||||||
| 60 | 600 | 610,0 | 5,0 | 6,3 | - | - | - | 56 | 57 | - | - | - | ||||||||
A dash in a box indicates a size that has not been standardized.