HG/T 20519.9-1992 Equipment Installation Drawing
time:
2024-08-14 10:09:22
- HG/T 20519.9-1992
- in force
Standard ID:
HG/T 20519.9-1992
Standard Name:
Equipment Installation Drawing
Chinese Name:
设备安装图
Standard category:
Chemical industry standards (HG)
-
Date of Release:
1993-01-18 -
Date of Implementation:
1993-04-01
Standard ICS number:
General, Terminology, Standardization, Documentation>>Technical Drawing>>01.100.01 Technical Drawing General 71.010China Standard Classification Number:
>>>>G0 Engineering Construction>>Raw Materials Industry, Communications, Broadcasting Engineering>>P72 Petrochemical, Chemical Engineering

Skip to download
Summary:
HG/T 20519.9-1992 Equipment Installation Drawing HG/T20519.9-1992 Standard Download Decompression Password: www.bzxz.net

Some standard content:
Equipment installation drawing
HG 20519. 9-92
1Overview
Equipment installation drawing
HG 20519.9-92
The design model of the equipment installation drawing refers to some equipment installation details that need to be designed by the device layout professionals, except for the equipment brackets and operating tables designed by the civil engineering or equipment professionals, such as the retaining frame at the top of the tower, the pads under the cold insulation equipment support, and the installation drawings of the purchased equipment spring brackets. In order to count materials and facilitate construction, installation drawings must be drawn in accordance with this regulation. 2 Drawing format and scale
The drawing format is generally A3 or A2. The scale is generally 1:20 or 1:10. 3Just above the title bar, a material table is listed, and its format and content are shown in the example figure. 4Instructions or notes
Instructions or notes should be placed above the material table to write technical requirements or construction requirements and the adopted standards and specifications.
See example drawing
TXXX cooling tower retaining frame installation drawingWww.bzxZ.net
4-M16 anchor bolts, exposed 40 on the foundation surface, pre-buried by civil engineering professionals, with nuts and washers. Welding procedures are in accordance with JB/Z105-73GB985-786-80. The roughness of the fur surface is plate surface, and the rest.
【Drawing number or standard number
T×××× cooling tower
Retaining frame installation drawing (example drawing)
Weight (kg)
Project name:
Design project:
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
HG 20519. 9-92
1Overview
Equipment installation drawing
HG 20519.9-92
The design model of the equipment installation drawing refers to some equipment installation details that need to be designed by the device layout professionals, except for the equipment brackets and operating tables designed by the civil engineering or equipment professionals, such as the retaining frame at the top of the tower, the pads under the cold insulation equipment support, and the installation drawings of the purchased equipment spring brackets. In order to count materials and facilitate construction, installation drawings must be drawn in accordance with this regulation. 2 Drawing format and scale
The drawing format is generally A3 or A2. The scale is generally 1:20 or 1:10. 3Just above the title bar, a material table is listed, and its format and content are shown in the example figure. 4Instructions or notes
Instructions or notes should be placed above the material table to write technical requirements or construction requirements and the adopted standards and specifications.
See example drawing
TXXX cooling tower retaining frame installation drawingWww.bzxZ.net
4-M16 anchor bolts, exposed 40 on the foundation surface, pre-buried by civil engineering professionals, with nuts and washers. Welding procedures are in accordance with JB/Z105-73GB985-786-80. The roughness of the fur surface is plate surface, and the rest.
【Drawing number or standard number
T×××× cooling tower
Retaining frame installation drawing (example drawing)
Weight (kg)
Project name:
Design project:
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 5290.2-2003 Parameters of electric spark forming machines Part 2: Double-column machine tools (moving spindle head type and cross table type)
- GB 5441.4-1985 Test methods for communication cables - Pulse method for coaxial end-to-end impedance and internal impedance non-uniformity test
- JB 4029-2000 Technical requirements for safety protection of grinding wheel guards of grinding machines
- JB/T 9754-1999 Technical requirements for repair welding of defects in grey iron castings for internal combustion engines
- GB/T 33182-2016 National fundamental scale maps—1∶5000 1∶10000 orthophoto maps
- GB 50167-1992 Specification for engineering photogrammetry
- JB/T 9012-1999 Side-mounted forklift
- JB/T 2462.1-1999 Parameters and dimensions of multi-axis turret power heads, common components of modular machine tools
- JB/T 10314.2-2002 Technical requirements for YRKK, YRKK-W series high voltage wound rotor three-phase asynchronous motors (frame size 355-630)
- JB/T 3042-1999 Parameter series of clamping cylinder for modular machine tools
- HG 2994-1987 Terminology of Textile Dyeing and Finishing Auxiliary Agents
- JB/T 6380-1992 Dam winch
- GB 4455-1994 Polyethylene blown film for agricultural use
- GB 18068-2000 Standard for sanitary protection distances in cement plants
- HG 2684-1995 Food additive diluted benzoyl peroxide
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com