GB 18529-2001 Occupational exposure limit of acetaldehyde in workplace air
time:
2024-08-05 22:29:01
- GB 18529-2001
- in force
Standard ID:
GB 18529-2001
Standard Name:
Occupational exposure limit of acetaldehyde in workplace air
Chinese Name:
车间空气中乙醛职业接触限值
Standard category:
National Standard (GB)
-
Date of Release:
2001-01-02 -
Date of Implementation:
2002-05-01
Standard ICS number:
Environmental protection, health and safety >> 13.100 Occupational safety, industrial hygieneChina Standard Classification Number:
Medicine, Health, Labor Protection>>Health>>C52 Labor Hygiene
alternative situation:
void;
publishing house:
China Standards PressISBN:
155066.1-18301Publication date:
2004-04-18
Release date:
2001-12-04Review date:
2004-10-14Drafting Organization:
Beijing Institute of Labor Hygiene and Occupational Disease Prevention and ControlFocal point Organization:
Ministry of HealthPublishing Department:
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of ChinaCompetent Authority:
Ministry of Health

Skip to download
Summary:
This standard specifies the maximum permissible concentration of acetaldehyde in the air of a workplace and the monitoring and testing methods. This standard applies to all types of industrial enterprises that produce and use acetaldehyde. GB 18529-2001 Occupational exposure limits for acetaldehyde in the air of a workplace GB18529-2001 Standard download decompression password: www.bzxz.net

Some standard content:
GB18529—2001
This standard is formulated for the first time based on the on-site labor hygiene and occupational epidemiological survey data, and with reference to foreign toxicological research data and occupational exposure limits: it is a health standard for workplace environmental monitoring and health supervision. This standard shall be implemented from May 1, 2002. Appendix A of this standard is the appendix of the standard.
This standard is proposed by the Ministry of Health of the People's Republic of China. The responsible unit for drafting this standard is Beijing Institute of Labor Hygiene and Occupational Disease Prevention and Control: The participating drafting unit is the Industrial Hygiene Section of the Safety and Technology Department of Daqing Petrochemical General Plant.
The main drafters of this standard are Guang Qingsheng, Cui Mingzhen, and Dong Dinglong. This standard is entrusted to the Institute of Labor Hygiene and Occupational Diseases of the Chinese Academy of Preventive Medicine for interpretation. 624
National Standard of the People's Republic of China
Occupational exposure limit foracetaldehydein the air of workplace
Occupational exposure limit foracetaldehydein the air of workplace
This standard specifies the maximum permissible concentration of acetaldehyde in the air of workplace and the monitoring and inspection methods. This standard is applicable to various industrial enterprises that produce and use acetaldehyde. Hygiene requirements
The maximum permissible concentration of acetaldehyde in the air of workplace is 45mg/m. 3 Monitoring and inspection methods
This standard recommends the use of gas chromatography, see Appendix A (Appendix to the standard). Approved by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on December 4, 2001-rrKAoNrKAca-
GB 18529—2001
Implementation on May 1, 2002
A1 Principle
GB 18529—2001
Appendix A
(Standard Appendix)
Determination of acetaldehyde concentration in air
Acetaldehyde in air is separated by polyethylene glycol 20 mesh chromatographic column and tested by flame ionization detector. The retention time is used for qualitative analysis and the peak height is used for quantitative analysis. A2 Instrumentswww.bzxz.net
A2.1 Syringe: 1 ml., J00 ml..
A2.2 Gas chromatograph: with flame ionization detector. Chromatographic column. Column length 3m. Inner diameter 4 mm. Stainless steel column. Polyethylene glycol 20: 6201 carrier 20, 100. Column temperature: 75C.
Vaporization chamber overflow: 150℃.
Detection chamber temperature: 150℃.
Carrier gas (nitrogen) flow rate: 38mL/min. A3 Reagents
A3.1 Acetaldehyde: chromatographic grade.
A3.2 Polyethylene glycol 20: chromatographic stationary liquid, A3.36201 carrier: 6080.
A4 Sampling
Use a 100mL syringe to draw and flush the sample point with on-site air three times, then take an air sample, put on a rubber cap, and place the syringe vertically. Analyze immediately after sampling.
A5 Analysis steps
45.1 Control test: Bring a 100nL syringe to the site, extract 100ml. clean air, and analyze it at the same time as the sample as a control. A5.2 Sample processing: Place the syringes of the sample and the control sample vertically, and record the temperature and atmospheric pressure of the laboratory. A5. 3 Drawing of the standard curve: Use a micro-syringe to take a certain amount of acetaldehyde at 18 ℃ (1 μl. The mass of acetaldehyde is 0.783mg at 18 C), inject it into a 100nL syringe, and use clean air to make a standard gas of a certain concentration. Take the above standard gas and use clean air to release it into 0.005, 0.05, 0.1 and 0.2g/ml acetaldehyde standard gas. Inject 1mL respectively, measure the retention time and peak height. Repeat the measurement 3 times for each concentration and take the average peak height. Plot the acetaldehyde content against the peak height to draw a standard curve. A5.4 Determination: Take 1 ml of sample and inject it. Determine under the conditions of the standard curve. Use retention time for qualitative analysis and peak height for quantitative analysis. Determine the aldehyde content from the standard curve.
A6 Calculation
A6.1 Convert the injection volume to the standard volume according to formula (A1). V = V, × 273 +7
Convert to the injection volume under standard conditions, L, where: V,
-the air temperature at the time of determination, ℃,
-the atmospheric pressure at the time of determination, kPa;
GB18529-2001
-the injection volume at temperature t℃ and pressure P, I. A6.2 Calculate the concentration of acetaldehyde in the air according to formula (A2). ×1 000
--Acetaldehyde content in air, mg/m;
m---Acetaldehyde content found on the standard curve #g;V. ——Converted into injection volume under standard state, mL. A7 Explanation
A7.1 The detection limit of this method is 0.3mg/m (direct injection of 1mL). A7.2 This method measures the instantaneous concentration of acetaldehyde. To comprehensively evaluate the air quality in the workshop, the number of samplings should be increased. A7.3 The sample should be analyzed as soon as possible on the same day. The syringe should be placed vertically during the transportation and storage of the sample. A7.4 The clean air used to prepare the standard gas and the control sample refers to the air that does not contain acetaldehyde or other interfering gases. 2
Time, min
1-Acetaldehyde; 2-Acetone; 3-Propylene aldehyde + 4 Methyl propylene ether + 7 Crotonaldehyde Figure A1
-rKAoNrKAca-
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
This standard is formulated for the first time based on the on-site labor hygiene and occupational epidemiological survey data, and with reference to foreign toxicological research data and occupational exposure limits: it is a health standard for workplace environmental monitoring and health supervision. This standard shall be implemented from May 1, 2002. Appendix A of this standard is the appendix of the standard.
This standard is proposed by the Ministry of Health of the People's Republic of China. The responsible unit for drafting this standard is Beijing Institute of Labor Hygiene and Occupational Disease Prevention and Control: The participating drafting unit is the Industrial Hygiene Section of the Safety and Technology Department of Daqing Petrochemical General Plant.
The main drafters of this standard are Guang Qingsheng, Cui Mingzhen, and Dong Dinglong. This standard is entrusted to the Institute of Labor Hygiene and Occupational Diseases of the Chinese Academy of Preventive Medicine for interpretation. 624
National Standard of the People's Republic of China
Occupational exposure limit foracetaldehydein the air of workplace
Occupational exposure limit foracetaldehydein the air of workplace
This standard specifies the maximum permissible concentration of acetaldehyde in the air of workplace and the monitoring and inspection methods. This standard is applicable to various industrial enterprises that produce and use acetaldehyde. Hygiene requirements
The maximum permissible concentration of acetaldehyde in the air of workplace is 45mg/m. 3 Monitoring and inspection methods
This standard recommends the use of gas chromatography, see Appendix A (Appendix to the standard). Approved by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on December 4, 2001-rrKAoNrKAca-
GB 18529—2001
Implementation on May 1, 2002
A1 Principle
GB 18529—2001
Appendix A
(Standard Appendix)
Determination of acetaldehyde concentration in air
Acetaldehyde in air is separated by polyethylene glycol 20 mesh chromatographic column and tested by flame ionization detector. The retention time is used for qualitative analysis and the peak height is used for quantitative analysis. A2 Instrumentswww.bzxz.net
A2.1 Syringe: 1 ml., J00 ml..
A2.2 Gas chromatograph: with flame ionization detector. Chromatographic column. Column length 3m. Inner diameter 4 mm. Stainless steel column. Polyethylene glycol 20: 6201 carrier 20, 100. Column temperature: 75C.
Vaporization chamber overflow: 150℃.
Detection chamber temperature: 150℃.
Carrier gas (nitrogen) flow rate: 38mL/min. A3 Reagents
A3.1 Acetaldehyde: chromatographic grade.
A3.2 Polyethylene glycol 20: chromatographic stationary liquid, A3.36201 carrier: 6080.
A4 Sampling
Use a 100mL syringe to draw and flush the sample point with on-site air three times, then take an air sample, put on a rubber cap, and place the syringe vertically. Analyze immediately after sampling.
A5 Analysis steps
45.1 Control test: Bring a 100nL syringe to the site, extract 100ml. clean air, and analyze it at the same time as the sample as a control. A5.2 Sample processing: Place the syringes of the sample and the control sample vertically, and record the temperature and atmospheric pressure of the laboratory. A5. 3 Drawing of the standard curve: Use a micro-syringe to take a certain amount of acetaldehyde at 18 ℃ (1 μl. The mass of acetaldehyde is 0.783mg at 18 C), inject it into a 100nL syringe, and use clean air to make a standard gas of a certain concentration. Take the above standard gas and use clean air to release it into 0.005, 0.05, 0.1 and 0.2g/ml acetaldehyde standard gas. Inject 1mL respectively, measure the retention time and peak height. Repeat the measurement 3 times for each concentration and take the average peak height. Plot the acetaldehyde content against the peak height to draw a standard curve. A5.4 Determination: Take 1 ml of sample and inject it. Determine under the conditions of the standard curve. Use retention time for qualitative analysis and peak height for quantitative analysis. Determine the aldehyde content from the standard curve.
A6 Calculation
A6.1 Convert the injection volume to the standard volume according to formula (A1). V = V, × 273 +7
Convert to the injection volume under standard conditions, L, where: V,
-the air temperature at the time of determination, ℃,
-the atmospheric pressure at the time of determination, kPa;
GB18529-2001
-the injection volume at temperature t℃ and pressure P, I. A6.2 Calculate the concentration of acetaldehyde in the air according to formula (A2). ×1 000
--Acetaldehyde content in air, mg/m;
m---Acetaldehyde content found on the standard curve #g;V. ——Converted into injection volume under standard state, mL. A7 Explanation
A7.1 The detection limit of this method is 0.3mg/m (direct injection of 1mL). A7.2 This method measures the instantaneous concentration of acetaldehyde. To comprehensively evaluate the air quality in the workshop, the number of samplings should be increased. A7.3 The sample should be analyzed as soon as possible on the same day. The syringe should be placed vertically during the transportation and storage of the sample. A7.4 The clean air used to prepare the standard gas and the control sample refers to the air that does not contain acetaldehyde or other interfering gases. 2
Time, min
1-Acetaldehyde; 2-Acetone; 3-Propylene aldehyde + 4 Methyl propylene ether + 7 Crotonaldehyde Figure A1
-rKAoNrKAca-
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB 5169.6-1985 Test method for poor contact of heaters used in fire hazard tests for electrical and electronic products
- GB/T 15436-1995 Determination of nitrogen oxides in ambient air - Saltzman method
- NY/T 5165-2002 Technical specification for breeding of snakehead fish for pollution-free food
- JB 20040-2004 Knife type particle crusher
- SJ 20665-1998 General specification for non-directional beacons
- JB/T 7947-1999 Isobaric welding torch and cutting torch
- GBZ 14-2002 Diagnostic criteria for occupational acute ammonia poisoning
- GB 15987-1995 Diagnostic criteria and management principles for infectious pulmonary tuberculosis
- GB 1094.3-1985 Power transformer Part 3 Insulation level and insulation test
- HG 3700-2002 Triclosan EC
- HG/T 2032-1999 Industrial cobalt acetate
- JB/T 6519-1992 Technical requirements for large and medium-sized three-phase asynchronous motors for fan coal mills
- GB/T 3471-1995 General rules for mooring and navigation tests of seagoing vessels
- NY 5110-2002 Environmental conditions for the production of pollution-free watermelon
- GB/T 17720-1999 Metallic coatings--Review of porosity tests
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com