HG/T 20519.29-1992 Pipe rack numbers and representation of pipe racks in piping layout drawings
time:
2024-08-14 09:54:35
- HG/T 20519.29-1992
- in force
Standard ID:
HG/T 20519.29-1992
Standard Name:
Pipe rack numbers and representation of pipe racks in piping layout drawings
Chinese Name:
管架编号和管道布置图中管架的表示法
Standard category:
Chemical industry standards (HG)
-
Date of Release:
1993-01-18 -
Date of Implementation:
1993-04-01
Standard ICS number:
General, Terminology, Standardization, Documentation>>Technical Drawing>>01.100.01 Technical Drawing General 71.010China Standard Classification Number:
>>>>G0 Engineering Construction>>Raw Materials Industry, Communications, Broadcasting Engineering>>P72 Petrochemical, Chemical Engineering
Skip to download
Summary:
HG/T 20519.29-1992 Pipe rack numbering and representation of pipe racks in piping layout drawings HG/T20519.29-1992 Standard download decompression password: www.bzxz.net
Some standard content:
Pipe rack numbers and representation of pipe racks in piping layout drawings
HG 20519.29-92
Pipe rack numbers and representation of pipe racks in piping layout drawings
HG 20519.29-92
1 Pipe rack number
1.0.1 Pipe rack number consists of five parts
.X-XXX
Pipe rack serial number
The last number of the pipeline layout drawing
The structure of the rooting part of the pipe rack
Pipe rack category
1.0.1.1 Pipe rack category
A——fixed rack
G——guide rack
R—sliding rack
H hanger
S——spring hanger
P—spring support
-special rack
(ANCHOR)
(GUIDE)
(RESTING)
(RIGID HANGER)
(SPRING HANGER)
(SPRING PEDESTAL)
(ESPECIALSUPPORT)
- Indicates axial limit frame (stop frame)
1.0.1.2 Structure of the rooting part of the pipe rack
C-— Indicates concrete structure
- Indicates ground foundation
S- Indicates steel structure
V—— Indicates equipment
W— Indicates wall
(CONCRETE)
(FOUNDATION)
(STEEL)
(VESSEL)
(WALL)
1.0.1.3 Area code: Indicated by one digit. 1.0.1.4
The tail number of the pipeline layout diagram: Indicated by a digit. 151
The serial number of the pipe rack
is represented by two digits, starting from 01 (it should be written separately according to the type of pipe rack and the structure of the rooting position). 2
The representation of the pipe rack in the pipeline layout drawing
The pipe rack is represented in the pipeline layout drawing by a legend, and the pipe rack number is marked next to it. Examples are as follows: Example 1:
GS-1011
Indicates that there is a pipe support (insulation, cold insulation pipe or large pipe end support) Example 2:
AF-1212
Indicates that there is no pipe support or other forms
Example 3:
RFi901
RS1804
Note: The circle diameter is 5mm.
indicates elbow bracket or lateral bracket
indicates a pipe rack number, including brackets for multiple pipes 152
2.0.2 Universal brackets on pipe corridors and outer pipes, only the numbers of the guide bracket and the fixed bracket are indicated. All those without numbers and only with pipe rack legends are sliding pipe brackets. The universal bracket numbers on pipe corridors and outer pipes are different from other brackets. The universal bracket numbers omit the area code and the last number of the layout drawing. The remaining two digits are as follows: GS-01 indicates a guide bracket without a pipe bracket on a steel structure. GS-11 indicates a guide bracket with a pipe bracket on a steel structure. AS-01 indicates a fixed bracket without a pipe bracket on a steel structure. AS-11 indicates a fixed bracket with a pipe bracket on a steel structure. However, standard types or elevated and extended pipe brackets other than non-universal brackets or pipe brackets still need to indicate the area code and the last number of the layout drawing. Www.bzxZ.net
2.0.3 The height of the column pipe rack shall not exceed 2.5m; if it exceeds 2.5m, it shall be designed by the civil engineering department. 2.0.4 When marking the pipe rack number in the pipeline layout drawing, it should be done at the same time as filling in the pipe rack table. The format of the pipe rack table is specified in HG20519.18-92. The coordinates or grid numbers shall be recorded so that the position of the pipe rack can be found and the arrangement order of the pipe rack numbers can be mastered during the design process.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
HG 20519.29-92
Pipe rack numbers and representation of pipe racks in piping layout drawings
HG 20519.29-92
1 Pipe rack number
1.0.1 Pipe rack number consists of five parts
.X-XXX
Pipe rack serial number
The last number of the pipeline layout drawing
The structure of the rooting part of the pipe rack
Pipe rack category
1.0.1.1 Pipe rack category
A——fixed rack
G——guide rack
R—sliding rack
H hanger
S——spring hanger
P—spring support
-special rack
(ANCHOR)
(GUIDE)
(RESTING)
(RIGID HANGER)
(SPRING HANGER)
(SPRING PEDESTAL)
(ESPECIALSUPPORT)
- Indicates axial limit frame (stop frame)
1.0.1.2 Structure of the rooting part of the pipe rack
C-— Indicates concrete structure
- Indicates ground foundation
S- Indicates steel structure
V—— Indicates equipment
W— Indicates wall
(CONCRETE)
(FOUNDATION)
(STEEL)
(VESSEL)
(WALL)
1.0.1.3 Area code: Indicated by one digit. 1.0.1.4
The tail number of the pipeline layout diagram: Indicated by a digit. 151
The serial number of the pipe rack
is represented by two digits, starting from 01 (it should be written separately according to the type of pipe rack and the structure of the rooting position). 2
The representation of the pipe rack in the pipeline layout drawing
The pipe rack is represented in the pipeline layout drawing by a legend, and the pipe rack number is marked next to it. Examples are as follows: Example 1:
GS-1011
Indicates that there is a pipe support (insulation, cold insulation pipe or large pipe end support) Example 2:
AF-1212
Indicates that there is no pipe support or other forms
Example 3:
RFi901
RS1804
Note: The circle diameter is 5mm.
indicates elbow bracket or lateral bracket
indicates a pipe rack number, including brackets for multiple pipes 152
2.0.2 Universal brackets on pipe corridors and outer pipes, only the numbers of the guide bracket and the fixed bracket are indicated. All those without numbers and only with pipe rack legends are sliding pipe brackets. The universal bracket numbers on pipe corridors and outer pipes are different from other brackets. The universal bracket numbers omit the area code and the last number of the layout drawing. The remaining two digits are as follows: GS-01 indicates a guide bracket without a pipe bracket on a steel structure. GS-11 indicates a guide bracket with a pipe bracket on a steel structure. AS-01 indicates a fixed bracket without a pipe bracket on a steel structure. AS-11 indicates a fixed bracket with a pipe bracket on a steel structure. However, standard types or elevated and extended pipe brackets other than non-universal brackets or pipe brackets still need to indicate the area code and the last number of the layout drawing. Www.bzxZ.net
2.0.3 The height of the column pipe rack shall not exceed 2.5m; if it exceeds 2.5m, it shall be designed by the civil engineering department. 2.0.4 When marking the pipe rack number in the pipeline layout drawing, it should be done at the same time as filling in the pipe rack table. The format of the pipe rack table is specified in HG20519.18-92. The coordinates or grid numbers shall be recorded so that the position of the pipe rack can be found and the arrangement order of the pipe rack numbers can be mastered during the design process.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GBZ 14-2002 Diagnostic criteria for occupational acute ammonia poisoning
- JB/T 7043-1993 Technical requirements for hydraulic axial piston pumps
- SY/T 10002-2000 Structural steel pipe manufacturing specification
- GB/T 13322-1991 Metal coating-Cd-Ti plating of low hydrogan embrittlement
- JB/T 7014-1993 Flat conveyor
- GB 18428-2001 Glass balls for automatic fire extinguishing systems
- JB/T 5239-1991 Technical requirements for diesel engine paper filter element diesel filter assembly
- GB/T 19602-2004 1,1-Difluoroethane (HFC-152a) for industrial use
- GB/T 19012-2008 Quality management—Customer satisfaction—Guidelines for complaints handling in organizations
- GB/T 6380-2008 Statistical interpretation of data - Detection and treatment of outliers in the sample from typeⅠextreme value distribution
- GB/T 8638.6-1988 Chemical analysis methods for nickel-based alloy powders - Titanium trichloride-potassium dichromate titration method for determination of iron content
- GB/T 3893-1998 Terminology for deck machinery in shipbuilding and offshore structures
- GB/T 11699-2003 Propeller shaft ends and hubs with a taper of 1:10 for inboard boats
- GBZ 101-2002 Diagnostic criteria for radiation-induced thyroid disease
- CJJ 67-1995 Landscape Architecture Legend Standard
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com