GB 16211-1996 Hygienic standard for long-term phosphorus in workshop air

time: 2024-08-06 06:40:25
  • GB 16211-1996
  • in force

Basic Information

standard classification number

  • Standard ICS number:

    Environmental protection, health and safety>>Air quality>>13.040.30 Air quality in the workplace
  • China Standard Classification Number:

    Medicine, Health, Labor Protection>>Health>>C52 Labor Hygiene

associated standards

Publication information

Other Information

  • Release date:

    1996-04-03
  • Review date:

    2004-10-14
  • Drafting Organization:

    School of Public Health, Peking University Medical College
  • Focal point Organization:

    Ministry of Health
  • Publishing Department:

    State Administration of Technical Supervision Ministry of Health of the People's Republic of China
  • Competent Authority:

    Ministry of Health
Introduction to standardsDescription (Translated English) / download

Skip to download

Summary:

This standard specifies the maximum permissible concentration of monocrotophos in workshop air and its monitoring and testing methods. This standard applies to enterprises and units that produce and use monocrotophos. GB 16211-1996 Hygienic standard for monocrotophos in workshop air GB16211-1996 Standard download decompression password: www.bzxz.net
Standard contentStandard content

Some standard content:

National Standard of the People's Republic of China
Health standard for monocrotophos in the air of workplace
Health standard for monocrotophos in the air of workplace Subject content and scope of application
This standard specifies the maximum allowable concentration of monocrotophos in the air of workplace and its monitoring and inspection methods. This standard applies to enterprises and units that produce and use monocrotophos. 2 Hygiene requirements
The maximum allowable concentration of monocrotophos in the air of workplace is 0.01mg/m (skin). Monitoring and inspection methods
The monitoring and inspection methods of this standard adopt gas chromatography. See Appendix A (supplement). 4 Supervision and implementation
Health supervision agencies at all levels are responsible for the implementation of this standard. Approved by the State Bureau of Technical Supervision on April 3, 1996 GB16211-1996
Implementation on September 1, 1996bzxz.net
A1 Principle
GB 16211--1996
Appendix A
Gas chromatography
(Supplement)
A1.1 Long-acting phosphorus in the air is separated by a V-210 column and detected by a flame photometric detector. The retention time is qualitative and the peak height is quantitative. A1.2 The detection limit of this method is 1μg/ml.
A2 Instruments
A2.1 Sampling tube (6mm inner diameter, 10cm long glass tube), filled with two sections of activated silica gel (20~40 mesh, 400mg in the front section and 100mg in the back section), the front and middle are blocked by glass wool, and the back end is fixed with foam plastic. A2.2 Micro syringe, 10μLc
A2.3 KD concentrator.
A2.4 Liquid rapid mixer.
A2.5 Atmospheric sampler (flow rate 0~2L/min). A2.6 Gas chromatograph, flame photometric detector, 526nm filter. Reagents
A3.1 (V-210 stationary phase.
A3.2 Gas chrom Q support, 60~~80 mesh. A3.3 Acetone, analytical grade.
A3.4 Long-acting phosphorus (purity 99.8%).
A4 Sampling
Remove the plastic caps at both ends of the silica gel sampling tube, connect it to the atmospheric sampler, sample at 1L/min for 100min, and cover the plastic cap of the sampling tube. Stable for 9 days below 37C.
A5 Analysis steps
A5.1 Chromatographic conditions
Chromatographic column: column Length 0.8m, inner diameter 3mm, glass column, 0V-210: GaschromQ carrier-2:100, column temperature 190C; vaporization chamber temperature 230℃;
Detection chamber temperature 230C;
d. Carrier gas (nitrogen): 90mL/min.
A5.2 Standard curve drawing
Prepare different concentrations of monocrotophos aqueous solution (1~10μg/mL), inject 1~ 5μL. Take the average peak height for each concentration by three injections. Draw a standard curve with the average peak height and injection volume (ng) in double logarithm. A5.3 Sample analysis
Collect the silica gel in the sampling tube at the front and back sections, and add 2-3mL acetone for desorption twice. Place the acetone in a KD concentrator tube and concentrate it to 0.2ml in a 70℃ water bath. Take 1-5μL for injection, and use retention time for qualitative analysis and peak height for quantitative analysis. 158
A6 Calculation||t t||Where: X---concentration of long-acting phosphorus in the air, mg/m~; GB16211-1996
A, A'--respectively the sample injection volume of the desorption sample before and after the silica gel, μl; XB
B, B\--respectively the fixed volume after desorption and concentration of the silica gel before and after the silica gel, mL; (\, \--respectively the long-acting phosphorus chromatographic measurement of the silica gel before and after the silica gel, ng; V--standard volume of collected gas, L. Additional remarks:
This standard is proposed by the Ministry of Health of the People's Republic of China. This standard is drafted by the School of Public Health of Beijing Medical University. The main drafters of this standard are Zhang Xian and Ruan Yongxiao. (A1)
This standard is interpreted by the Institute of Labor Hygiene and Occupational Diseases, Chinese Academy of Preventive Medicine, the technical unit entrusted by the Ministry of Health. 459
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]