
YC/T 37.6-2002 Determination of physical properties of filter rods Part 6: Roundness
time:
2024-08-09 17:21:32
- YC/T 37.6-2002
- in force
Standard ID:
YC/T 37.6-2002
Standard Name:
Determination of physical properties of filter rods Part 6: Roundness
Chinese Name:
滤棒物理性能的测定 第6部分:圆度
Standard category:
Tobacco Industry Standard (YC)
-
Date of Release:
2002-05-14 -
Date of Implementation:
2002-07-01
Standard ICS number:
Agriculture >> 65.160 Tobacco, tobacco products and tobacco industry equipmentChina Standard Classification Number:
Food>>Cigarette Making>>X85 Cigarette Making Comprehensive
alternative situation:
YC/T 37.6-1996
publishing house:
China Standards PressISBN:
155066.2-14541Publication date:
2002-06-01
Drafter:
Feng Xiaomin, Xing Jun, Zhao Hang, et al.Drafting Organization:
National Tobacco Standardization Technical Committee (TC 144)Focal point Organization:
National Tobacco Standardization Technical Committee (TC 144)Proposing Organization:
National Tobacco Quality Supervision and Inspection CenterPublishing Department:
State Tobacco Monopoly Administration

Skip to download
Summary:
This part of YC/T 37 specifies the method for determining the roundness of filter rods. This part is applicable to filter rods of various specifications. YC/T 37.6-2002 Determination of physical properties of filter rods Part 6: Roundness YC/T37.6-2002 Standard download decompression password: www.bzxz.net

Some standard content:
ICS65.160
Registration number: 10499—2002
Tobacco Industry Standard of the People's Republic of China
YC/T37.6-2002
Replaces YC/T37.6-1996
Test of filters physical characteristics--Part 6:Circularity
Published on 2002-05-14
State Tobacco Monopoly Administration
Implementation on 2002-07-01
YC/T 37.6—2002
This part is the sixth part in the YC/T37 "Determination of physical properties of filter rods" series of standards. This series of standards consists of seven parts: Determination of physical properties of filter rods
Part 1: Lengthwww.bzxz.net
Photoelectric method
Determination of physical properties of filter rods
Part 2: Circumference
Determination of physical properties of filter rods
Part 3: Absorption resistance
Determination of physical properties of filter rods
Part 4: Hardness
Determination of physical properties of filter rods Part 5: Moisture content Determination of physical properties of filter rods Part 6: Roundness Determination of physical properties of filter rods Part 7: Appearance laser method
This part replaces YC/T37.6--1996 "Determination of physical properties of filter rods Part 6: Roundness". Compared with YC/T37.6--1996, this part has the following main changes: the photoelectric method is specified to determine the roundness of filter rods; the maximum diameter minus the minimum diameter of the filter rod is used instead of the determination method of the difference between the two diameters of the filter rod overlap; the one-point method replaces the two-point method.
This part was proposed by the State Tobacco Monopoly Administration. This part is under the jurisdiction of the National Tobacco Standardization Technical Committee (TC144). The drafting unit of this part: National Tobacco Quality Supervision and Inspection Center. The main drafters of this part: Feng Xiaomin, Xing Jun, Zhao Hang, Zhou Decheng, Li Xiaohui. The previous versions of the standard replaced by this part are: YC/T37.6--1996.560
1 Scope
Determination of physical properties of filter rods
Part 6: Roundness
This part of YC/T37 specifies the determination method of filter rod roundness. This part is applicable to filter rods of various specifications. 2 Normative references
YC/T 37. 6--2002
The clauses in the following documents become the clauses of this part through reference in this part of YC/T37. For any dated reference, all subsequent amendments (excluding errata) or revisions are not applicable to this part. However, parties to an agreement based on this part are encouraged to study whether the latest versions of these documents can be used. For any undated reference, the latest version applies to this part. GB/T16447 Atmospheric environment for conditioning and testing of tobacco and tobacco products (idtISO3402) 3 Principle
Use projection or photoelectric methods to measure the maximum and minimum diameters of the filter rod respectively, and the difference between the two diameters is the roundness. 4 Instruments and equipment
4.1 The instrument required for measuring roundness should meet the following requirements: - An optical system that can generate parallel light (laser or ordinary light): It can perform at least 100 rotational projection or scanning measurements on the sample; - A probe: During the measurement process, the sample rotates continuously for at least 180° - Photoelectric receiving device and data processing system; - The accuracy of the instrument measurement result (diameter): 0.01mm. 4.2 Standard rod: Accuracy (diameter) 0.003mm. 5 Determination steps
According to GI3/T16447, adjust the sample and test under the corresponding environmental conditions. 5.1 Use a standard rod to calibrate the instrument.
5.2 Place the sample in the probe so that the parallel light beam shines on the middle of the sample. 5.3 When the sample rotates, project or scan the sample. 5.4 The photoelectric receiving device and data processing system give the maximum and minimum values of the sample diameter, or directly give the difference between the maximum diameter and the minimum diameter (roundness).
6 Result expression
6.1 Calculation
The roundness of each filter rod is calculated according to formula (1):
Roundness = [D, -- D,i
YC/T37.6—2002
Where:
D—-the maximum value of the diameter of each filter rod, in millimeters (mm); Dz.-the minimum value of the diameter of each filter rod, in millimeters (mm). 6.2
The measurement results shall be expressed in millimeters, accurate to 0.01mm. Measurement report
The measurement report shall include the following contents:
YC/T37 Part No.
Specimen marking and description;
--Measurement time, instrument used and model;--Measurement environment conditions and measurement results.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Registration number: 10499—2002
Tobacco Industry Standard of the People's Republic of China
YC/T37.6-2002
Replaces YC/T37.6-1996
Test of filters physical characteristics--Part 6:Circularity
Published on 2002-05-14
State Tobacco Monopoly Administration
Implementation on 2002-07-01
YC/T 37.6—2002
This part is the sixth part in the YC/T37 "Determination of physical properties of filter rods" series of standards. This series of standards consists of seven parts: Determination of physical properties of filter rods
Part 1: Lengthwww.bzxz.net
Photoelectric method
Determination of physical properties of filter rods
Part 2: Circumference
Determination of physical properties of filter rods
Part 3: Absorption resistance
Determination of physical properties of filter rods
Part 4: Hardness
Determination of physical properties of filter rods Part 5: Moisture content Determination of physical properties of filter rods Part 6: Roundness Determination of physical properties of filter rods Part 7: Appearance laser method
This part replaces YC/T37.6--1996 "Determination of physical properties of filter rods Part 6: Roundness". Compared with YC/T37.6--1996, this part has the following main changes: the photoelectric method is specified to determine the roundness of filter rods; the maximum diameter minus the minimum diameter of the filter rod is used instead of the determination method of the difference between the two diameters of the filter rod overlap; the one-point method replaces the two-point method.
This part was proposed by the State Tobacco Monopoly Administration. This part is under the jurisdiction of the National Tobacco Standardization Technical Committee (TC144). The drafting unit of this part: National Tobacco Quality Supervision and Inspection Center. The main drafters of this part: Feng Xiaomin, Xing Jun, Zhao Hang, Zhou Decheng, Li Xiaohui. The previous versions of the standard replaced by this part are: YC/T37.6--1996.560
1 Scope
Determination of physical properties of filter rods
Part 6: Roundness
This part of YC/T37 specifies the determination method of filter rod roundness. This part is applicable to filter rods of various specifications. 2 Normative references
YC/T 37. 6--2002
The clauses in the following documents become the clauses of this part through reference in this part of YC/T37. For any dated reference, all subsequent amendments (excluding errata) or revisions are not applicable to this part. However, parties to an agreement based on this part are encouraged to study whether the latest versions of these documents can be used. For any undated reference, the latest version applies to this part. GB/T16447 Atmospheric environment for conditioning and testing of tobacco and tobacco products (idtISO3402) 3 Principle
Use projection or photoelectric methods to measure the maximum and minimum diameters of the filter rod respectively, and the difference between the two diameters is the roundness. 4 Instruments and equipment
4.1 The instrument required for measuring roundness should meet the following requirements: - An optical system that can generate parallel light (laser or ordinary light): It can perform at least 100 rotational projection or scanning measurements on the sample; - A probe: During the measurement process, the sample rotates continuously for at least 180° - Photoelectric receiving device and data processing system; - The accuracy of the instrument measurement result (diameter): 0.01mm. 4.2 Standard rod: Accuracy (diameter) 0.003mm. 5 Determination steps
According to GI3/T16447, adjust the sample and test under the corresponding environmental conditions. 5.1 Use a standard rod to calibrate the instrument.
5.2 Place the sample in the probe so that the parallel light beam shines on the middle of the sample. 5.3 When the sample rotates, project or scan the sample. 5.4 The photoelectric receiving device and data processing system give the maximum and minimum values of the sample diameter, or directly give the difference between the maximum diameter and the minimum diameter (roundness).
6 Result expression
6.1 Calculation
The roundness of each filter rod is calculated according to formula (1):
Roundness = [D, -- D,i
YC/T37.6—2002
Where:
D—-the maximum value of the diameter of each filter rod, in millimeters (mm); Dz.-the minimum value of the diameter of each filter rod, in millimeters (mm). 6.2
The measurement results shall be expressed in millimeters, accurate to 0.01mm. Measurement report
The measurement report shall include the following contents:
YC/T37 Part No.
Specimen marking and description;
--Measurement time, instrument used and model;--Measurement environment conditions and measurement results.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- HG/T 2712-1995 Determination of viscosity of liquid and solution phenolic resins
- JB/T 8667.1-1997 Technical requirements for large three-phase synchronous motors TK series
- JB/T 6417-1992 Air filter for air conditioning
- DL/T 700.3-1999 Power goods and materials code Part 3 spare parts
- GB 5083-1999 General principles for safety and sanitation design of production equipment
- HG/T 3642-1999 Water treatment agent acrylic acid-2-methyl-2-acrylamidopropanesulfonic acid copolymer
- GB 11297.11-1989 Test method for dielectric constant of pyroelectric materials
- JB/T 8027.1-1999 Machine tool fixture parts and component supports
- MT/T 809-1999 General provisions for coal preparation test methods
- JB/T 5889-1991 绝缘子用有色金属铸件 技术条件
- SY 5728-1995 Safety Management Regulations for Beach and Sea Oil Seismic Teams
- JB/T 7386.1-1994 Terminology of Industrial Automation Instruments Temperature Instruments
- HGJ 206-1992 Chemical Machinery Installation Engineering Construction and Acceptance Specifications Small and Medium Piston Compressors
- GB/T 2787-1981 Alphanumeric layout of keyboards for seven-bit coded character sets for information processing and exchange
- JB/T 5783-1991 Technical requirements for sealed glow plugs
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]