GB/T 5540-1985 Disperse dyes - Determination of dispersion properties - Double filter paper filtration method
time:
2024-08-04 15:53:37
- GB/T 5540-1985
- Abolished
Standard ID:
GB/T 5540-1985
Standard Name:
Disperse dyes - Determination of dispersion properties - Double filter paper filtration method
Chinese Name:
分散染料分散性能测定方法 双层滤纸过滤法
Standard category:
National Standard (GB)
-
Date of Release:
1985-10-29 -
Date of Implementation:
1986-08-01 -
Date of Expiration:
2008-06-01
Standard ICS number:
Paint and pigment industry>>Paint ingredients>>87.060.10 Pigments and fillersChina Standard Classification Number:
Chemicals>>Coatings, Pigments, Dyes>>G55 Basic Standards and General Methods for Dyes
alternative situation:
Replaced by GB/T 5540-2007Procurement status:
≈AATCC 146-79
Release date:
1985-10-29Review date:
2004-10-14Drafting Organization:
Shenyang Research Institute of Chemical IndustryFocal point Organization:
National Dye Standardization Technical CommitteePublishing Department:
China Petroleum and Chemical Industry AssociationCompetent Authority:
China Petroleum and Chemical Industry Association
Skip to download
Summary:
GB/T 5540-1985 Disperse dyes dispersion performance determination method Double filter paper filtration method GB/T5540-1985 standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Method for Determination of Dispersibllty for Disperse Dye
Double-layer Filter Paper Filtration Method
Determlnation of dispersibllty for disperse dye (Filter test of double fllter papers )UDC868. White: 535.6
GB 554085
This standard is applicable to the determination of the dispersibility of disperse dyes. The double-layer filter paper filtration method is used to compare the filter paper residue and filtration time with the "residue five-level card" and "filtration time level" to grade the dispersibility of disperse dyes. Materials and Instruments
Porcelain funnel: Büchner porcelain funnel with a diameter of 120mm. Filter paper, double ring brand with a diameter of 11omm fast qualitative filter paper and medium-speed qualitative filter paper. Stainless steel ring: outer diameter 110mm, inner diameter 102mm, height 8mm. c.
Suction filter bottle, capacity 1000m1.
Vacuum gauge.
Vacuum pump.
Vacuum control valve.
Vacuum-resistant hose.
Stopwatch.
Beaker: 400ml.
Day and a half, the feeling is not more than 0.1g.
Electromagnetic stirrer.
Volume sachets: 250ml.
Constant temperature water bath.
The installation of vacuum filtration device is shown in the figure:
Suction bottle
2 Reagents and solutions
National Bureau of Standards 1985-10-29 Issued
Screw rinse bottle
Quick rinse bottlebzxz.net
Vacuum filter
1986-08-01 Implementation
GB 5540-85
a, disodium diaminetetraacetic acid (EDTA) (GB1401-78): chemically pure, 0.25g/I solution. b, glacial acetic acid (GB 676-78): chemically pure, 10% solution. 3 Determination steps
3.1 Preparation of disperse dye suspension (hereinafter referred to as dye solution). Weigh 2.0±0.1 μg of dye (based on 100 points of dyeing intensity) into a 40ml beaker, mix it into a paste with 5ml of hot EDTA solution (50℃, 0.25g/L), then sieve and dilute it with the same EDTA solution to a total volume of 200ml, stir it on an electromagnetic stirrer for 3-5min, and then adjust the pH value to 4.5-5.0 with 10% acetic acid solution, then place the beaker in a constant temperature water bath, and under constant stirring, bring the temperature to 71℃ within 5min for filtration.
8.2 Filtration of disperse dye suspension
Put 250ml of 71℃ distilled water into a porcelain funnel, preheat the funnel and stainless steel ring at the same time, start the vacuum pump after 25±10s to completely extract the water, cut off the vacuum, remove the funnel and stainless steel ring, put the medium-speed filter paper on the fast filter paper, put them into the Büchner funnel together, and press the filter paper tightly with the stainless steel ring. While the vacuum pump is running, pour the dye solution heated to 71°C into the funnel for filtration and start timing with a stopwatch. When the appearance of the filter paper changes from yellow to dry, the end point is reached. Record the elapsed time, stop the pump, take out the filter paper residue and let it air dry for 1 second before rating.
Note: (1) The capacity of the buffer bottle used in the vacuum system is 2500ml. After the vacuum system is lit, the highest point of vacuum should be adjusted to 60mm with a valve. The vacuum degree of the impurity when the liquid is poured into the funnel for 10 to 15 seconds is 56±10㎡m<. ② The entire operation from dyeing to filtration is required to be completed within 15 minutes. ③ The operation should be strictly carried out in accordance with the test method. 4 Rating
Compare the filtration time and the filter paper residue with the "filtration time level" and "residue five-level card" for rating. The dispersion performance of the dye is expressed by the filtration time level/residue number. The filtration time level is specified as:
Grade A - - 0 ~ 24S
B level—25 ~ 495
C level——50~74s
D level——-75~120s
E level——large T120s
The levels of the residue level card are as follows:
5 level—excellent
4 level—good
3 level—medium
2 level—poor
1 level—worst
Note: The text of this standard and the five-level residue card are issued separately. The text part is published by China Standards Press and issued by Xinhua Bookstore, and the five-level residue card is reproduced and issued by Shenyang Chemical Industry Research Institute. Additional notes:
GB 5540—85
This standard was proposed by the Ministry of Chemical Industry of the People's Republic of China and is under the jurisdiction of Shenyang Huagong Research Institute of the Ministry of Chemical Industry. Shenyang Chemical Research Institute is responsible for drafting this standard. The main drafter of this standard is Li Wenzhen.
This standard was formulated with reference to the American Association of Textile Chemists and Dyers standard AATCC1461979 "Diffusion of Disperse Dyes".
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Method for Determination of Dispersibllty for Disperse Dye
Double-layer Filter Paper Filtration Method
Determlnation of dispersibllty for disperse dye (Filter test of double fllter papers )UDC868. White: 535.6
GB 554085
This standard is applicable to the determination of the dispersibility of disperse dyes. The double-layer filter paper filtration method is used to compare the filter paper residue and filtration time with the "residue five-level card" and "filtration time level" to grade the dispersibility of disperse dyes. Materials and Instruments
Porcelain funnel: Büchner porcelain funnel with a diameter of 120mm. Filter paper, double ring brand with a diameter of 11omm fast qualitative filter paper and medium-speed qualitative filter paper. Stainless steel ring: outer diameter 110mm, inner diameter 102mm, height 8mm. c.
Suction filter bottle, capacity 1000m1.
Vacuum gauge.
Vacuum pump.
Vacuum control valve.
Vacuum-resistant hose.
Stopwatch.
Beaker: 400ml.
Day and a half, the feeling is not more than 0.1g.
Electromagnetic stirrer.
Volume sachets: 250ml.
Constant temperature water bath.
The installation of vacuum filtration device is shown in the figure:
Suction bottle
2 Reagents and solutions
National Bureau of Standards 1985-10-29 Issued
Screw rinse bottle
Quick rinse bottlebzxz.net
Vacuum filter
1986-08-01 Implementation
GB 5540-85
a, disodium diaminetetraacetic acid (EDTA) (GB1401-78): chemically pure, 0.25g/I solution. b, glacial acetic acid (GB 676-78): chemically pure, 10% solution. 3 Determination steps
3.1 Preparation of disperse dye suspension (hereinafter referred to as dye solution). Weigh 2.0±0.1 μg of dye (based on 100 points of dyeing intensity) into a 40ml beaker, mix it into a paste with 5ml of hot EDTA solution (50℃, 0.25g/L), then sieve and dilute it with the same EDTA solution to a total volume of 200ml, stir it on an electromagnetic stirrer for 3-5min, and then adjust the pH value to 4.5-5.0 with 10% acetic acid solution, then place the beaker in a constant temperature water bath, and under constant stirring, bring the temperature to 71℃ within 5min for filtration.
8.2 Filtration of disperse dye suspension
Put 250ml of 71℃ distilled water into a porcelain funnel, preheat the funnel and stainless steel ring at the same time, start the vacuum pump after 25±10s to completely extract the water, cut off the vacuum, remove the funnel and stainless steel ring, put the medium-speed filter paper on the fast filter paper, put them into the Büchner funnel together, and press the filter paper tightly with the stainless steel ring. While the vacuum pump is running, pour the dye solution heated to 71°C into the funnel for filtration and start timing with a stopwatch. When the appearance of the filter paper changes from yellow to dry, the end point is reached. Record the elapsed time, stop the pump, take out the filter paper residue and let it air dry for 1 second before rating.
Note: (1) The capacity of the buffer bottle used in the vacuum system is 2500ml. After the vacuum system is lit, the highest point of vacuum should be adjusted to 60mm with a valve. The vacuum degree of the impurity when the liquid is poured into the funnel for 10 to 15 seconds is 56±10㎡m<. ② The entire operation from dyeing to filtration is required to be completed within 15 minutes. ③ The operation should be strictly carried out in accordance with the test method. 4 Rating
Compare the filtration time and the filter paper residue with the "filtration time level" and "residue five-level card" for rating. The dispersion performance of the dye is expressed by the filtration time level/residue number. The filtration time level is specified as:
Grade A - - 0 ~ 24S
B level—25 ~ 495
C level——50~74s
D level——-75~120s
E level——large T120s
The levels of the residue level card are as follows:
5 level—excellent
4 level—good
3 level—medium
2 level—poor
1 level—worst
Note: The text of this standard and the five-level residue card are issued separately. The text part is published by China Standards Press and issued by Xinhua Bookstore, and the five-level residue card is reproduced and issued by Shenyang Chemical Industry Research Institute. Additional notes:
GB 5540—85
This standard was proposed by the Ministry of Chemical Industry of the People's Republic of China and is under the jurisdiction of Shenyang Huagong Research Institute of the Ministry of Chemical Industry. Shenyang Chemical Research Institute is responsible for drafting this standard. The main drafter of this standard is Li Wenzhen.
This standard was formulated with reference to the American Association of Textile Chemists and Dyers standard AATCC1461979 "Diffusion of Disperse Dyes".
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- QB/T 2186-1995 Determination of nitrogen content in hydrolyzed protein solution by ammonia sensitive electrode method
- SJ/T 11084-1996 Detail specification for electronic components-Electronic tube of type FU-100F (Applicable for certification)
- JB/T 5948-1991 Technical specifications for caliper disc brakes for engineering machinery
- HG 21505-1992 Combined sight glass
- JB/T 9154-1999 Fork chain, scraper and sprocket for buried scraper conveyor
- GB 4556-2001 Fire protection for reciprocating internal combustion engines
- GB 13042-2008 Packaging containers - Tinplate aerosol can
- GB/T 8593.1-1998 Earth-moving machinery operator control and other display symbols Part 1: General symbols
- GB/T 16305-1996 Torsional vibration damper
- JB/T 10192-2000 Technical requirements for small incinerators
- YS/T 455.5-2003 Test methods for aluminium foil Part 5 Test method for DC resistance of aluminium foil
- SY/T 5587.16-1993 Procedures for routine well repair and casing scraping in oil and water wells
- GB/T 9341-2000 Test method for bending properties of plastics
- GB/T 15503-1995 水质 钒的测定 钽试剂(BPHA)萃取分光光度法
- GB/T 15487-1995 容积式压缩机流量测量方法
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com