JB/T 2001.62-1999 Electromagnetic distributor for water system pump station (PN=20, 31.5MPa)
time:
2024-08-12 07:58:23
- JB/T 2001.62-1999
- in force
Standard ID:
JB/T 2001.62-1999
Standard Name:
Electromagnetic distributor for water system pump station (PN=20, 31.5MPa)
Chinese Name:
水系统 泵站用电磁分配器(PN=20、31.5MPa)
Standard category:
Machinery Industry Standard (JB)
-
Date of Release:
1999-06-28 -
Date of Implementation:
2000-01-01
Standard ICS number:
Fluid systems and general parts >> 23.100 Fluid power systemsChina Standard Classification Number:
Machinery>>General Parts>>J20 Hydraulic and Pneumatic Devices
alternative situation:
JB 2065-1984
Focal point Organization:
Metallurgical Equipment Standardization Technical CommitteePublishing Department:
Metallurgical Equipment Standardization Technical Committee
Skip to download
Summary:
JB/T 2001.62-1999 This standard is a revision of JB 2065-84 "Electromagnetic distributor for hydraulic pump station (Pg=31.5×100000Pa)". This standard specifies the type, size and technical requirements of electromagnetic distributors for pump stations with nominal pressure of 20 and 31.5MPa. Type I of this standard is that the water inlet valve is normally open when the power is off, and is suitable for controlling the minimum liquid level valve; Type II of this standard is that the water inlet valve is normally closed when the power is off, and is suitable for controlling the circulation valve. This standard was first issued in 1984. JB/T 2001.62-1999 Electromagnetic distributor for water system pump station (PN=20, 31.5MPa) JB/T2001.62-1999 standard download decompression password: www.bzxz.net
Some standard content:
IC.S$ 23.110
Machinery Industry Standard of the People's Republic of China
JB/T 2001.1~2001.74—1999
Water system assembly and parts1999-06-28 Issued
State Machinery Industry Bureau
2(0-01-U1 Implementation
■ Scope
Machinery Industry Standard of the People's Republic of China
Water system
Electromagnetic distributor for pump station
Water svsiem-Sojedold distributor for accurqulatorPN=2031.5 MPa]
JB:201.62—1499
In the standard specification, the type of single-distributor for the system with a public pressure of 20 and 31.5M is used. There is no technical requirement for the size! In the standard type, the system is powered off and the water inlet is open. The minimum liquid level must be controlled under the appropriate pressure. The water inlet of this standard type is normally closed when the system is powered off, and is suitable for controlling the circulation valve. 2 Types and sizesbzxz.net
2.! The type and size of the electromagnetic distributor of type 1 shall be determined according to the source of the sewage, 2.2 The type and size of the electromagnetic distributor of type 1 shall be determined according to the provisions of Figure 2, 2.3 and the magnetic distributor is 103kB.
3 Technical requirements
3.1 The nominal pressure is 31.5MPa. The test pressure is 42MPa. The nominal pressure is 20MPa, the test pressure is 30MPa, 3.? The damping screw () of the short-stroke device is debugged It should be fully opened at the same time, and then gradually increase the damping to an appropriate level: 3.3 It is recommended to connect capacitors in parallel between each phase of the three-phase AC transformer to reduce residual magnetism. 34 In order to reduce the heating of the electromagnetic distributor type, each phase coil is connected in reverse when energized, and a resistor can be connected in series to keep the power at the bottom of the small line. When the power is off, the resistor is disconnected to prepare for starting. 3.5 The bottom plane of the electric distributor bracket should be 300 higher than the reference ground. 4 Marking example: Type II electromagnetic distributor:
Inductive distributor type JB/T2001.61999
Guodong Machinery Industry Bureau approved on June 2, 1999 170
24H0-01-U1 implementation
JB/T3001.67—199*
? First instance—1
JB/T 2001.62—1999
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Machinery Industry Standard of the People's Republic of China
JB/T 2001.1~2001.74—1999
Water system assembly and parts1999-06-28 Issued
State Machinery Industry Bureau
2(0-01-U1 Implementation
■ Scope
Machinery Industry Standard of the People's Republic of China
Water system
Electromagnetic distributor for pump station
Water svsiem-Sojedold distributor for accurqulatorPN=2031.5 MPa]
JB:201.62—1499
In the standard specification, the type of single-distributor for the system with a public pressure of 20 and 31.5M is used. There is no technical requirement for the size! In the standard type, the system is powered off and the water inlet is open. The minimum liquid level must be controlled under the appropriate pressure. The water inlet of this standard type is normally closed when the system is powered off, and is suitable for controlling the circulation valve. 2 Types and sizesbzxz.net
2.! The type and size of the electromagnetic distributor of type 1 shall be determined according to the source of the sewage, 2.2 The type and size of the electromagnetic distributor of type 1 shall be determined according to the provisions of Figure 2, 2.3 and the magnetic distributor is 103kB.
3 Technical requirements
3.1 The nominal pressure is 31.5MPa. The test pressure is 42MPa. The nominal pressure is 20MPa, the test pressure is 30MPa, 3.? The damping screw () of the short-stroke device is debugged It should be fully opened at the same time, and then gradually increase the damping to an appropriate level: 3.3 It is recommended to connect capacitors in parallel between each phase of the three-phase AC transformer to reduce residual magnetism. 34 In order to reduce the heating of the electromagnetic distributor type, each phase coil is connected in reverse when energized, and a resistor can be connected in series to keep the power at the bottom of the small line. When the power is off, the resistor is disconnected to prepare for starting. 3.5 The bottom plane of the electric distributor bracket should be 300 higher than the reference ground. 4 Marking example: Type II electromagnetic distributor:
Inductive distributor type JB/T2001.61999
Guodong Machinery Industry Bureau approved on June 2, 1999 170
24H0-01-U1 implementation
JB/T3001.67—199*
? First instance—1
JB/T 2001.62—1999
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- QB/T 2306-1997 Thermoresistant α-amylase preparation
- JB/T 7948.5-1999 Chemical analysis methods for melting fluxes - Sulfosalicylic acid photometric method for determination of iron oxide content
- HG/T 23017-1999 Safety regulations for earthwork in factories
- GB/T 3356-1999 Test method for bending properties of unidirectional fiber reinforced plastics
- GB/T 15565-1995 Graphical symbol-Terms
- GB/T 8565.2-1988 Information processing - Coded character set for text communication - Part 2: Graphic character set
- SJ 2534.4-1985 Test procedures for antennas-Antenna-range evaluation
- JB/T 9722-2001 Definition and symbols of dimensions of earth-moving machinery main engine
- JB 20002.5-2004 ampoule printing machine
- QB/T 3505-1999 Font paperboard
- QB 1429-1992 Industrial sodium alkyl sulfonate
- JB/T 51127-1999 Reliability assessment of small and medium power diesel products
- GB/T 14634.5-2002 Test method for rare earth trichromatic phosphors for lamps - Density determination
- QB/T 2463.3-1999 Co-extrusion method for rigid polyvinyl chloride low foaming sheet
- JB/T 9617-1999 DC motor armature winding turn-to-turn insulation test specification
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com