GB 4893.6-1985 Determination of gloss of furniture surface paint film
time:
2024-08-05 03:28:41
- GB 4893.6-1985
- in force
Standard ID:
GB 4893.6-1985
Standard Name:
Determination of gloss of furniture surface paint film
Chinese Name:
家具表面漆膜光泽测定法
Standard category:
National Standard (GB)
-
Date of Release:
1985-02-01 -
Date of Implementation:
1985-04-01
Standard ICS number:
Household and commercial equipment, entertainment, sports >> 97.140 FurnitureChina Standard Classification Number:
Light Industry, Cultural and Living Supplies>>Furniture>>Y80 Furniture General
Release date:
1985-02-01Review date:
2004-10-14Drafter:
An DaipingDrafting Organization:
Shanghai Furniture Research InstituteFocal point Organization:
Shanghai Furniture Research InstituteProposing Organization:
Ministry of Light Industry of the People's Republic of ChinaPublishing Department:
National Bureau of StandardsCompetent Authority:
China Light Industry Federation
Skip to download
Summary:
This standard is applicable to the determination of the gloss of paint films on wooden furniture and other wooden furniture parts. A photoelectric gloss meter is used. The gloss value is expressed as a percentage of the ratio of the regular reflection light on the paint film surface to the regular reflection light on the standard board surface under the same conditions. GB 4893.6-1985 Determination of gloss of paint films on furniture surfaces GB4893.6-1985 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Method for Determination of Gloss Value of Surface Coatings on Furniture
Furniture-Assessment of Gloss Value of Surface Coatings
UDC 684.4 : 667
GB 4893.6-85
This standard applies to the determination of the gloss value of the surface coatings on wooden furniture and other wooden furniture parts. A photoelectric gloss meter is used. The gloss value is expressed as a percentage of the ratio of the regular reflection light quantity on the surface of the coating film to the regular reflection light quantity on the surface of the standard plate under the same conditions. 1 Equipment and Materials
1.1 The photoelectric gloss meter requires the instrument reproducibility to be not less than 2%. It is recommended to use the GZ-Ⅱ photoelectric gloss meter. 1.2 Flannel or lens cleaning paper.
2 Sample
2.1 The specification is 250mm×200mm.
2.2 The sample should be stored for at least 10 days after the coating is completed and can be tested only after it is completely dry. 2.3 The surface of the sample should be flat, and the paint film should be free of defects such as scratches and bubbles. 2.4 When sending samples, a test report should be attached, including the name of the paint, a brief coating process, production time, etc. 3 Test conditions
The test room temperature is 20±2℃, and the relative humidity is 60%~70%. 4 Test steps
According to the instrument's instructions, select the range and calibrate the instrument pointer to the calibration value of the standard plate. 4.2 Wipe the surface of the sample clean, and take three test areas for each sample, one in the center of the sample and the other two at any position. 4.3 Place the probe on the test area and make the wood grain direction follow the direction of the incident and reflected light in the probe. Read the gloss value (the reading is accurate to 1%), and take the arithmetic mean of the 3-point readings. 4.4
4.5 Each time a sample is measured, calibrate it with a standard plate. Test report
The test report shall include the following contents:
Test date,
The name of the coating material of the sample and a brief coating process, c.
Storage time of the sample after coating,
Test results.
Promulgated by the National Bureau of Standards on February 1, 1985
Implemented on April 10, 1985
GB 4893.6—85.
Appendix A
Grading standard of gloss value of Jiayi surface paint film
(reference)
A1 Gloss value is graded according to the angle of 60° when the light is projected onto the sample, see the table below. Bei Ze value
Jiang Zi Yi
High gloss
Additional instructions:
Aperture matte
Significant aperture mattebzxZ.net
This standard is proposed by the Ministry of Light Industry of the People's Republic of China and is technically managed by Shanghai Furniture Research Institute. This standard is drafted by Shanghai Furniture Research Institute. The main drafter of this standard is An Daiping.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Method for Determination of Gloss Value of Surface Coatings on Furniture
Furniture-Assessment of Gloss Value of Surface Coatings
UDC 684.4 : 667
GB 4893.6-85
This standard applies to the determination of the gloss value of the surface coatings on wooden furniture and other wooden furniture parts. A photoelectric gloss meter is used. The gloss value is expressed as a percentage of the ratio of the regular reflection light quantity on the surface of the coating film to the regular reflection light quantity on the surface of the standard plate under the same conditions. 1 Equipment and Materials
1.1 The photoelectric gloss meter requires the instrument reproducibility to be not less than 2%. It is recommended to use the GZ-Ⅱ photoelectric gloss meter. 1.2 Flannel or lens cleaning paper.
2 Sample
2.1 The specification is 250mm×200mm.
2.2 The sample should be stored for at least 10 days after the coating is completed and can be tested only after it is completely dry. 2.3 The surface of the sample should be flat, and the paint film should be free of defects such as scratches and bubbles. 2.4 When sending samples, a test report should be attached, including the name of the paint, a brief coating process, production time, etc. 3 Test conditions
The test room temperature is 20±2℃, and the relative humidity is 60%~70%. 4 Test steps
According to the instrument's instructions, select the range and calibrate the instrument pointer to the calibration value of the standard plate. 4.2 Wipe the surface of the sample clean, and take three test areas for each sample, one in the center of the sample and the other two at any position. 4.3 Place the probe on the test area and make the wood grain direction follow the direction of the incident and reflected light in the probe. Read the gloss value (the reading is accurate to 1%), and take the arithmetic mean of the 3-point readings. 4.4
4.5 Each time a sample is measured, calibrate it with a standard plate. Test report
The test report shall include the following contents:
Test date,
The name of the coating material of the sample and a brief coating process, c.
Storage time of the sample after coating,
Test results.
Promulgated by the National Bureau of Standards on February 1, 1985
Implemented on April 10, 1985
GB 4893.6—85.
Appendix A
Grading standard of gloss value of Jiayi surface paint film
(reference)
A1 Gloss value is graded according to the angle of 60° when the light is projected onto the sample, see the table below. Bei Ze value
Jiang Zi Yi
High gloss
Additional instructions:
Aperture matte
Significant aperture mattebzxZ.net
This standard is proposed by the Ministry of Light Industry of the People's Republic of China and is technically managed by Shanghai Furniture Research Institute. This standard is drafted by Shanghai Furniture Research Institute. The main drafter of this standard is An Daiping.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 14806-2003 AC ventilating fans and speed regulators for household and similar purposes
- JB/T 6367-1992 Type and size of protective drag chain
- GB/T 27040-2010 Conformity assessment—General requirements for peer assessment of conformity assessment bodies and accreditation bodies
- SY 5469-1992 Rotary Drilling Equipment Hose
- QB/T 2289.2-1997 Gardening tools - Mulberry shears
- JB/T 9918.2-1999 Technical requirements for high precision hob grinders
- GB 11217-1989 General provisions for monitoring effluent from nuclear facilities
- JB/T 8905.4-1999 Set-type reducer for crane
- GB/T 5687.3-1985 Chemical analysis methods for ferrochrome - Molybdenum blue photometric method for determination of phosphorus content
- GB 18468-2001 Hygienic standard for p-dichlorobenzene in indoor air
- SJ/Z 3206.2-1989 Laser source and its performance requirements for determination of emision spectrum
- GB 4793.5-2001 Particular requirements for hand-held probes for safe electrical measurements and tests on electrical equipment for measurement, control and laboratory use
- HG/T 3611-1999 Test method for simulated walking (life) of footwear
- HG 21603-1999 Swing cover quick open stainless steel hand hole
- GB/T 15829.2-1995 Soldering flux resins for soldering
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com