Blank detail specification for compact fluorescent lamps
time:
2024-07-14 16:39:20
- SJ/T 10547-1994
- in force
Standard ID:
SJ/T 10547-1994
Standard Name:
Blank detail specification for compact fluorescent lamps
Chinese Name:
紧凑型荧光灯管空白详细规范
Standard category:
Electronic Industry Standard (SJ)
-
Date of Release:
1994-08-08 -
Date of Implementation:
1994-12-01
China Standard Classification Number:
General>>Standardization Management and General Provisions>>A01 Technical Management

Skip to download
Summary:
SJ/T 10547-1994 Blank Detailed Specification for Compact Fluorescent Lamps SJ/T10547-1994 Standard Download Decompression Password: www.bzxz.net

Some standard content:
Electronic Industry Standard of the People's Republic of China
SJ/T10547—94
Blank detail specification for compact fluorescent lamps
Blank detail specification for compact fluorescent lamps1994-08-08 Issued
Implemented on 1994-12-01
Issued by the Ministry of Electronics Industry of the People's Republic of China Electronic Industry Standard of the People's Republic of China
Blank detail specification for compact fluorescent lamps
Biank detail specification for compact fluorescent lampsSJ/T10547—94
This blank detailed specification stipulates the basic principles for formulating the detailed specification for compact fluorescent lamps. It is used together with SJ/T10546 "General Specification for Special Fluorescent Lamps" to constitute all the requirements for compact fluorescent lamps. The format adopted by the detailed specification and the contents included should be consistent with this blank detailed specification. Notes on the front page of a blank detailed specification:
The numbers between the square brackets on the front page of a blank detailed specification shall correspond to the following: Identification of the detailed specification
[1] Name of the body authorized to issue this detailed specification. [2] Number and year of the detailed specification. [3] Number and year of the general specification.
[4] Number and year of the blank detailed specification. Identification of fluorescent tubes:
[5] Brief description of the fluorescent tube, cathode type, starting method, etc. [6] Model of the fluorescent tube.
[7 Outline drawing with main dimensions.
Ministry of Electronics Industry of the People's Republic of China
Approved on August 8, 1994
Implemented on December 1, 1994
Blank detailed specification homepage
SJ/T10547—94
Performance (not for inspection)
1.1 General performance
1.1.1 Quality
1.2 Starting characteristics
1.2.1 Starting voltage
1.2.2 At starting 1.3 Electrical parameters
1.3.1 Lamp power
1.3.2 Lamp terminal voltage
1.3.3 Working current
1.3.4 Preheating current
1.4 Light parameters
1.4.1 Luminous flux
2 Information
2.1.1 Product mark
Manufacturer's trademark;
Product model,
Manufacture date.
Packaging mark
Manufacturer’s name and trademark;
Product name and model;
Number of this standard;
Number of lamp tubes;
SJ/T10547—94
Minimum value
Nominal value
Maximum value
The packaging box should have signs such as “Handle with care” and “Keep away from moisture” as specified in GB191 “Picture mark for packaging, storage and transportation”. 2.2 Ordering information
The ordering party should fill in the following information on the order form: a.
Required product model:
Number and release date of detailed specifications;
2.3 Related documents
Packaging, storage and transportation pictorial signs
SJ/T10546
General specification for special fluorescent tubes
2.4 Additional information (not for inspection)
Note: "*" indicates the content that should be filled in the detailed specifications. 3
2.5 Installation location
3 Test items and inspection requirements
SJ/T10547-94
The test conditions and inspection requirements are given in the table below. According to the requirements of the specific model, the test conditions used should be specified in the detailed specifications and be consistent with the corresponding test method provisions in SJ/T10546. Unless otherwise specified, all referenced article numbers should use the corresponding SJ/T10546 article numbers. Group A - Batch Inspection
All tests are non-destructive (ND) reference
Inspection or test
Group A1
Appearance quality
Group A2
Starting voltage
Starting time
Group A3
Insulation resistance
SJ/T10546
Test conditions
As specified
As specified
As specified
As specified
Minimum value
All tests are non-destructive (ND) reference
Inspection or test
Group B31
Electrode leads of lamp tube||tt ||Fixed mass
Structural dimensions
Assembly deviation of lamp holder and glass tube
B2 grouping
Lamp power
Lamp terminal voltage
SJ/T10546
Test conditions
As per regulations
As per regulations
As per regulations
As per regulations
Minimum value
Maximum value
As per regulations
Inspection requirements
Batch inspection
Maximum value
As per drawing requirements
As per regulationsbzxz.net
Note: "" indicates the content that should be filled in the detailed specification. Inspection
·Unit
Inspection or test
B3 group
Luminous flux of lamp
Color coordinates of lamp:
Target value
Color tolerance
SJ/T10546
Test conditions
As specified
As specified
SJ/T10547-94
Minimum value
Maximum value
Note: "" indicates the content to be filled in the detailed specification. Group C—Periodic Inspection
Those with mark (D) are destructive tests
Inspection or test
Group C1
Fire and flame retardancy (D)
Leakage distance of lamp holder
Temperature rise of lamp holder
Moisture resistance of lamp holder
Group C2
Life (D)
SJ/T10546
Note: ①p——Test period (in months). ②nSample size (in pieces).
?cNumber of qualified judgments.
4 Delayed delivery
According to regulations
According to regulations
According to regulations
According to regulations
According to regulations
According to regulations
Minimum value
Maximum deviation
According to regulations
According to regulations
According to regulations
According to regulations
According to regulations
According to regulations
For lamps that have passed the quality consistency inspection and have a storage period of more than 12 months, the following items must be re-inspected before delivery. Appearance quality;
b. Starting voltage.
Additional remarks:
This specification is under the jurisdiction of the Electronic Standardization Institute of the Ministry of Electronics Industry. This specification was drafted by the Standardization Institute of the Ministry of Electronics Industry and Weihai Beiyang Electric Group Corporation. The main drafters of this standard are Gao Fucai, Lai Wanqiong and Wang Haijian.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
SJ/T10547—94
Blank detail specification for compact fluorescent lamps
Blank detail specification for compact fluorescent lamps1994-08-08 Issued
Implemented on 1994-12-01
Issued by the Ministry of Electronics Industry of the People's Republic of China Electronic Industry Standard of the People's Republic of China
Blank detail specification for compact fluorescent lamps
Biank detail specification for compact fluorescent lampsSJ/T10547—94
This blank detailed specification stipulates the basic principles for formulating the detailed specification for compact fluorescent lamps. It is used together with SJ/T10546 "General Specification for Special Fluorescent Lamps" to constitute all the requirements for compact fluorescent lamps. The format adopted by the detailed specification and the contents included should be consistent with this blank detailed specification. Notes on the front page of a blank detailed specification:
The numbers between the square brackets on the front page of a blank detailed specification shall correspond to the following: Identification of the detailed specification
[1] Name of the body authorized to issue this detailed specification. [2] Number and year of the detailed specification. [3] Number and year of the general specification.
[4] Number and year of the blank detailed specification. Identification of fluorescent tubes:
[5] Brief description of the fluorescent tube, cathode type, starting method, etc. [6] Model of the fluorescent tube.
[7 Outline drawing with main dimensions.
Ministry of Electronics Industry of the People's Republic of China
Approved on August 8, 1994
Implemented on December 1, 1994
Blank detailed specification homepage
SJ/T10547—94
Performance (not for inspection)
1.1 General performance
1.1.1 Quality
1.2 Starting characteristics
1.2.1 Starting voltage
1.2.2 At starting 1.3 Electrical parameters
1.3.1 Lamp power
1.3.2 Lamp terminal voltage
1.3.3 Working current
1.3.4 Preheating current
1.4 Light parameters
1.4.1 Luminous flux
2 Information
2.1.1 Product mark
Manufacturer's trademark;
Product model,
Manufacture date.
Packaging mark
Manufacturer’s name and trademark;
Product name and model;
Number of this standard;
Number of lamp tubes;
SJ/T10547—94
Minimum value
Nominal value
Maximum value
The packaging box should have signs such as “Handle with care” and “Keep away from moisture” as specified in GB191 “Picture mark for packaging, storage and transportation”. 2.2 Ordering information
The ordering party should fill in the following information on the order form: a.
Required product model:
Number and release date of detailed specifications;
2.3 Related documents
Packaging, storage and transportation pictorial signs
SJ/T10546
General specification for special fluorescent tubes
2.4 Additional information (not for inspection)
Note: "*" indicates the content that should be filled in the detailed specifications. 3
2.5 Installation location
3 Test items and inspection requirements
SJ/T10547-94
The test conditions and inspection requirements are given in the table below. According to the requirements of the specific model, the test conditions used should be specified in the detailed specifications and be consistent with the corresponding test method provisions in SJ/T10546. Unless otherwise specified, all referenced article numbers should use the corresponding SJ/T10546 article numbers. Group A - Batch Inspection
All tests are non-destructive (ND) reference
Inspection or test
Group A1
Appearance quality
Group A2
Starting voltage
Starting time
Group A3
Insulation resistance
SJ/T10546
Test conditions
As specified
As specified
As specified
As specified
Minimum value
All tests are non-destructive (ND) reference
Inspection or test
Group B31
Electrode leads of lamp tube||tt ||Fixed mass
Structural dimensions
Assembly deviation of lamp holder and glass tube
B2 grouping
Lamp power
Lamp terminal voltage
SJ/T10546
Test conditions
As per regulations
As per regulations
As per regulations
As per regulations
Minimum value
Maximum value
As per regulations
Inspection requirements
Batch inspection
Maximum value
As per drawing requirements
As per regulationsbzxz.net
Note: "" indicates the content that should be filled in the detailed specification. Inspection
·Unit
Inspection or test
B3 group
Luminous flux of lamp
Color coordinates of lamp:
Target value
Color tolerance
SJ/T10546
Test conditions
As specified
As specified
SJ/T10547-94
Minimum value
Maximum value
Note: "" indicates the content to be filled in the detailed specification. Group C—Periodic Inspection
Those with mark (D) are destructive tests
Inspection or test
Group C1
Fire and flame retardancy (D)
Leakage distance of lamp holder
Temperature rise of lamp holder
Moisture resistance of lamp holder
Group C2
Life (D)
SJ/T10546
Note: ①p——Test period (in months). ②nSample size (in pieces).
?cNumber of qualified judgments.
4 Delayed delivery
According to regulations
According to regulations
According to regulations
According to regulations
According to regulations
According to regulations
Minimum value
Maximum deviation
According to regulations
According to regulations
According to regulations
According to regulations
According to regulations
According to regulations
For lamps that have passed the quality consistency inspection and have a storage period of more than 12 months, the following items must be re-inspected before delivery. Appearance quality;
b. Starting voltage.
Additional remarks:
This specification is under the jurisdiction of the Electronic Standardization Institute of the Ministry of Electronics Industry. This specification was drafted by the Standardization Institute of the Ministry of Electronics Industry and Weihai Beiyang Electric Group Corporation. The main drafters of this standard are Gao Fucai, Lai Wanqiong and Wang Haijian.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 9871-1999 Accuracy classification of metal cutting machine tools
- JB/T 7974-1999 Cast iron plate
- JB/T 5893.1-1991 电瓷用原料 绥中长石粉
- JB/T 6141.2-1992 Carburizing quality inspection of heavy-duty gears
- JB/T 8562-1997 Specifications for zinc-aluminum alloy cage materials for rolling bearings
- NY/T 1113-2006 Terms of microbial fertilizer
- HG 21514-1995 Types and technical requirements of manholes and handholes made of carbon steel and low alloy steel
- GB/T 13417-1992 Contents list for scientific and technical periodicals
- GB 16198-1996 Hygienic standard for cotton dust in workshop air
- GB/T 2625-1981 Graphic symbols and text codes for process detection and control flow charts
- JB/T 8461-1996 Hydraulic taper sleeve
- MT/T 412-1995 Flameproof low voltage terminal blocks for electrical equipment
- HJ/T 173-2005 Technical specifications for development of environmental reference materials
- GB/T 27827-2011 Chemicals—Test method of in vivo sister chromatid exchange
- GB/T 18978.10-2004 Ergonomic requirements for office work with visual display terminals (VDTs)-Part 10:Dialogue prinip
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]