GB 9278-1988 Temperature and humidity for condition conditioning and testing of paint samples
time:
1988-04-19 16:00:00
- GB 9278-1988
- Abolished
Standard ID:
GB 9278-1988
Standard Name:
Temperature and humidity for condition conditioning and testing of paint samples
Chinese Name:
涂料试样状态调节和试验的温湿度
Standard category:
National Standard (GB)
-
Date of Release:
1988-04-19 -
Date of Implementation:
1989-01-01 -
Date of Expiration:
2008-10-01
Standard ICS number:
Coatings and Pigments Industry>>87.040 Coatings and VarnishesChina Standard Classification Number:
Chemical Industry>>Coatings, Pigments, Dyes>>G50 Basic Standards and General Methods for Coatings
alternative situation:
Replaced by GB/T 9278-2008Procurement status:
=ISO 3270-84
Release date:
1988-06-04Review date:
2004-10-14Drafting Organization:
Coatings Research Institute of the Ministry of Chemical IndustryFocal point Organization:
National Coatings and Pigments Standardization Technical CommitteePublishing Department:
National Bureau of StandardsCompetent Authority:
China Petroleum and Chemical Industry Association

Skip to download
Summary:
This standard specifies the general temperature and relative humidity conditions for conditioning and testing of paints, varnishes and their raw materials. This standard applies to liquid and powder paints and varnishes, as well as to their wet or dry films and their raw materials. GB 9278-1988 Temperature and humidity for condition adjustment and testing of paint samples GB9278-1988 Standard download and decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Temperatures and humidities for conditioning and testing of paint specimensUDC667.6
GB9278—88www.bzxz.net
This standard is equivalent to the international standard ISO3270-1984 "Paints, varnishes and their raw materials - Temperature and humidity for conditioning and testing".
1 Main content and scope of application
This standard specifies the general temperature and relative humidity conditions for condition conditioning and testing of paints, varnishes and their raw materials. This standard applies to liquid and powder paints and varnishes, as well as to their wet or dry films and their raw materials. 2 Definition
2.1 Condition adjustment environment
The condition adjustment environment is the environment in which the specimen or specimen is maintained before being tested. It is characterized by the specified values ??of one or two parameters of temperature and relative humidity, and the parameter values ??remain within the specified range within a predetermined time. The selected parameter values ??and length of time depend on the nature of the sample or specimen to be tested.
Note: ① The term conditioning refers to the entire operation of placing specimens and specimens under specified conditions of temperature and humidity before testing, and keeping them in this environment for a predetermined time. ② The adjustment state can be carried out in the laboratory, or in a special sealed "state adjustment box" or in a test chamber. 2.2 Test environment
The test environment is the environment to which the sample or specimen is exposed during the entire test period. It is characterized by the specified values ??of one or two parameters of temperature and relative humidity, and maintaining them within a predetermined range. Note: The test is either carried out in the laboratory or in a special so-called "state conditioning box" or in a test chamber. The choice depends on the nature of the specimen or test piece and the conditions of the test itself. For example, if the performance of the specimen or specimen does not change significantly during the test, it is not necessary to strictly control the test environment. 3 Temperature and humidity for condition adjustment and testing
3.1 Standard environmental conditions (should be adopted whenever possible) temperature 23±2℃, relative humidity 50%±5%. 3.2 The standard temperature is 23±2℃, and the relative humidity is the ambient humidity. Note: For some tests, the temperature control range is more stringent. For example: when testing viscosity or consistency, the recommended control range is a maximum of ±0.5°C. 3.3 Other conditions
3.3.1 For certain areas where it is difficult to maintain the standard environmental conditions of Articles 3.1 and 3.2, and for non-arbitration purposes, other conditions may be specified, but they shall be noted in the test report.
3.3.2 For those environmental conditions where neither temperature nor relative humidity need to be controlled, if the temperature and humidity are known, they should be noted in the test report.
4 Condition adjustment
4.1 Condition adjustment time shall be specified by the specific test method considered, approved by the Ministry of Chemical Industry of the People's Republic of China on 1.988-04-19 and implemented on 1989-01-01||tt| |GB9278-88
2 The relevant parts of the specimen and the instrument should be placed in a state-adjusted environment so that they can reach equilibrium with the environment as quickly as possible. The specimens should be protected from direct sunlight and the environment should be kept clean. The test panels should be separated from each other and from the walls of the condition conditioning box by a distance of at least 20 mm. 5 Test
Unless otherwise specified, the specimen shall be tested in the same environment as its condition. If the standard environmental conditions specified in Article 3.1 are used for condition adjustment and testing, the test report shall state: The condition is adjusted for hours under the standard environmental conditions consistent with this national standard, and then the test is carried out. If the standard environment specified in Article 3.1 is not used, conditions, and other conditions are selected, the test report should indicate the conditions used. Additional notes:
This standard is under the jurisdiction of the National Coatings and Pigments Standardization Technical Committee. This standard is drafted by the Coatings Industry Research Institute of the Ministry of Chemical Industry. The main drafter of this standard is Song Jianguo.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Temperatures and humidities for conditioning and testing of paint specimensUDC667.6
GB9278—88www.bzxz.net
This standard is equivalent to the international standard ISO3270-1984 "Paints, varnishes and their raw materials - Temperature and humidity for conditioning and testing".
1 Main content and scope of application
This standard specifies the general temperature and relative humidity conditions for condition conditioning and testing of paints, varnishes and their raw materials. This standard applies to liquid and powder paints and varnishes, as well as to their wet or dry films and their raw materials. 2 Definition
2.1 Condition adjustment environment
The condition adjustment environment is the environment in which the specimen or specimen is maintained before being tested. It is characterized by the specified values ??of one or two parameters of temperature and relative humidity, and the parameter values ??remain within the specified range within a predetermined time. The selected parameter values ??and length of time depend on the nature of the sample or specimen to be tested.
Note: ① The term conditioning refers to the entire operation of placing specimens and specimens under specified conditions of temperature and humidity before testing, and keeping them in this environment for a predetermined time. ② The adjustment state can be carried out in the laboratory, or in a special sealed "state adjustment box" or in a test chamber. 2.2 Test environment
The test environment is the environment to which the sample or specimen is exposed during the entire test period. It is characterized by the specified values ??of one or two parameters of temperature and relative humidity, and maintaining them within a predetermined range. Note: The test is either carried out in the laboratory or in a special so-called "state conditioning box" or in a test chamber. The choice depends on the nature of the specimen or test piece and the conditions of the test itself. For example, if the performance of the specimen or specimen does not change significantly during the test, it is not necessary to strictly control the test environment. 3 Temperature and humidity for condition adjustment and testing
3.1 Standard environmental conditions (should be adopted whenever possible) temperature 23±2℃, relative humidity 50%±5%. 3.2 The standard temperature is 23±2℃, and the relative humidity is the ambient humidity. Note: For some tests, the temperature control range is more stringent. For example: when testing viscosity or consistency, the recommended control range is a maximum of ±0.5°C. 3.3 Other conditions
3.3.1 For certain areas where it is difficult to maintain the standard environmental conditions of Articles 3.1 and 3.2, and for non-arbitration purposes, other conditions may be specified, but they shall be noted in the test report.
3.3.2 For those environmental conditions where neither temperature nor relative humidity need to be controlled, if the temperature and humidity are known, they should be noted in the test report.
4 Condition adjustment
4.1 Condition adjustment time shall be specified by the specific test method considered, approved by the Ministry of Chemical Industry of the People's Republic of China on 1.988-04-19 and implemented on 1989-01-01||tt| |GB9278-88
2 The relevant parts of the specimen and the instrument should be placed in a state-adjusted environment so that they can reach equilibrium with the environment as quickly as possible. The specimens should be protected from direct sunlight and the environment should be kept clean. The test panels should be separated from each other and from the walls of the condition conditioning box by a distance of at least 20 mm. 5 Test
Unless otherwise specified, the specimen shall be tested in the same environment as its condition. If the standard environmental conditions specified in Article 3.1 are used for condition adjustment and testing, the test report shall state: The condition is adjusted for hours under the standard environmental conditions consistent with this national standard, and then the test is carried out. If the standard environment specified in Article 3.1 is not used, conditions, and other conditions are selected, the test report should indicate the conditions used. Additional notes:
This standard is under the jurisdiction of the National Coatings and Pigments Standardization Technical Committee. This standard is drafted by the Coatings Industry Research Institute of the Ministry of Chemical Industry. The main drafter of this standard is Song Jianguo.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB 5023.4-1997 Polyvinyl chloride insulated cables of rated voltage 450/750V and below Part 4: Sheathed cables for fixed wiring
- GB/T 11446.4-1997 Test method for resistivity of electronic grade water
- GB/T 8220.1-1998 Chemical analysis of bismuth - Bisaldehyde oxalyl dihydrazone spectrophotometric method for the determination of copper content
- JB/T 10165.2-1999 Technical requirements for CNC longitudinal cutting automatic lathes
- JB/T 6636-1993 Thin-wall sealed bearings for robots
- GB/T 8193-1987 Determination of total hydrocarbons in diesel engine exhaust - Hydrogen flame ionization method
- JB/T 8726-1998 Mechanical seal chamber dimensions
- HG 2507-1993 S109 vanadium catalyst for sulfuric acid production
- GB/T 29186.6-2021 Evaluation of brand value elements—Part 6:Intangible elements
- JB/T 2436.1-1992 Copper crimping terminals for conductors Part 1: Copper crimping terminals for conductors with a size of 0.5 to 6.0 mm2
- JB/T 1626-2002 Method for compiling product models of industrial boilers
- GB 50050-1995 Design specification for industrial circulating cooling water treatment
- JB/T 8718-1998 Rail-type rock drill
- GB/T 4517-1995 Test method for feeding direction stability of household sewing machines
- JG/T 24-2000 Synthetic resin emulsion sand wall building paint JG/T24-2000
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]