GB 9278-1988 Temperature and humidity for condition conditioning and testing of paint samples
time:
1988-04-19 16:00:00
- GB 9278-1988
- Abolished
Standard ID:
GB 9278-1988
Standard Name:
Temperature and humidity for condition conditioning and testing of paint samples
Chinese Name:
涂料试样状态调节和试验的温湿度
Standard category:
National Standard (GB)
-
Date of Release:
1988-04-19 -
Date of Implementation:
1989-01-01 -
Date of Expiration:
2008-10-01
Standard ICS number:
Coatings and Pigments Industry>>87.040 Coatings and VarnishesChina Standard Classification Number:
Chemical Industry>>Coatings, Pigments, Dyes>>G50 Basic Standards and General Methods for Coatings
alternative situation:
Replaced by GB/T 9278-2008Procurement status:
=ISO 3270-84
Release date:
1988-06-04Review date:
2004-10-14Drafting Organization:
Coatings Research Institute of the Ministry of Chemical IndustryFocal point Organization:
National Coatings and Pigments Standardization Technical CommitteePublishing Department:
National Bureau of StandardsCompetent Authority:
China Petroleum and Chemical Industry Association
Skip to download
Summary:
This standard specifies the general temperature and relative humidity conditions for conditioning and testing of paints, varnishes and their raw materials. This standard applies to liquid and powder paints and varnishes, as well as to their wet or dry films and their raw materials. GB 9278-1988 Temperature and humidity for condition adjustment and testing of paint samples GB9278-1988 Standard download and decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China
Temperatures and humidities for conditioning and testing of paint specimensUDC667.6
GB9278—88
This standard is equivalent to the international standard ISO3270-1984 "Paints, varnishes and their raw materials - Temperature and humidity for conditioning and testing".
1 Main content and scope of application
This standard specifies the general temperature and relative humidity conditions for condition conditioning and testing of paints, varnishes and their raw materials. This standard applies to liquid and powder paints and varnishes, as well as to their wet or dry films and their raw materials. 2 Definition
2.1 Condition adjustment environment
The condition adjustment environment is the environment in which the specimen or specimen is maintained before being tested. It is characterized by the specified values ??of one or two parameters of temperature and relative humidity, and the parameter values ??remain within the specified range within a predetermined time. The selected parameter values ??and length of time depend on the nature of the sample or specimen to be tested.
Note: ① The term conditioning refers to the entire operation of placing specimens and specimens under specified conditions of temperature and humidity before testing, and keeping them in this environment for a predetermined time. ② The adjustment state can be carried out in the laboratory, or in a special sealed "state adjustment box" or in a test chamber. 2.2 Test environment
The test environment is the environment to which the sample or specimen is exposed during the entire test period. It is characterized by the specified values ??of one or two parameters of temperature and relative humidity, and maintaining them within a predetermined range. Note: The test is either carried out in the laboratory or in a special so-called "state conditioning box" or in a test chamber. The choice depends on the nature of the specimen or test piece and the conditions of the test itself. For example, if the performance of the specimen or specimen does not change significantly during the test, it is not necessary to strictly control the test environment. 3 Temperature and humidity for condition adjustment and testing
3.1 Standard environmental conditions (should be adopted whenever possible) temperature 23±2℃, relative humidity 50%±5%. 3.2 The standard temperature is 23±2℃, and the relative humidity is the ambient humidity. Note: For some tests, the temperature control range is more stringent. For example: when testing viscosity or consistency, the recommended control range is a maximum of ±0.5°C. 3.3 Other conditions
3.3.1 For certain areas where it is difficult to maintain the standard environmental conditions of Articles 3.1 and 3.2, and for non-arbitration purposes, other conditions may be specified, but they shall be noted in the test report.
3.3.2 For those environmental conditions where neither temperature nor relative humidity need to be controlled, if the temperature and humidity are known, they should be noted in the test report.
4 Condition adjustment
4.1 Condition adjustment time shall be specified by the specific test method considered, approved by the Ministry of Chemical Industry of the People's Republic of China on 1.988-04-19 and implemented on 1989-01-01||tt| |GB9278-88wwW.bzxz.Net
2 The relevant parts of the specimen and the instrument should be placed in a state-adjusted environment so that they can reach equilibrium with the environment as quickly as possible. The specimens should be protected from direct sunlight and the environment should be kept clean. The test panels should be separated from each other and from the walls of the condition conditioning box by a distance of at least 20 mm. 5 Test
Unless otherwise specified, the specimen shall be tested in the same environment as its condition. If the standard environmental conditions specified in Article 3.1 are used for condition adjustment and testing, the test report shall state: The condition is adjusted for hours under the standard environmental conditions consistent with this national standard, and then the test is carried out. If the standard environment specified in Article 3.1 is not used, conditions, and other conditions are selected, the test report should indicate the conditions used. Additional notes:
This standard is under the jurisdiction of the National Coatings and Pigments Standardization Technical Committee. This standard is drafted by the Coatings Industry Research Institute of the Ministry of Chemical Industry. The main drafter of this standard is Song Jianguo.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Temperatures and humidities for conditioning and testing of paint specimensUDC667.6
GB9278—88
This standard is equivalent to the international standard ISO3270-1984 "Paints, varnishes and their raw materials - Temperature and humidity for conditioning and testing".
1 Main content and scope of application
This standard specifies the general temperature and relative humidity conditions for condition conditioning and testing of paints, varnishes and their raw materials. This standard applies to liquid and powder paints and varnishes, as well as to their wet or dry films and their raw materials. 2 Definition
2.1 Condition adjustment environment
The condition adjustment environment is the environment in which the specimen or specimen is maintained before being tested. It is characterized by the specified values ??of one or two parameters of temperature and relative humidity, and the parameter values ??remain within the specified range within a predetermined time. The selected parameter values ??and length of time depend on the nature of the sample or specimen to be tested.
Note: ① The term conditioning refers to the entire operation of placing specimens and specimens under specified conditions of temperature and humidity before testing, and keeping them in this environment for a predetermined time. ② The adjustment state can be carried out in the laboratory, or in a special sealed "state adjustment box" or in a test chamber. 2.2 Test environment
The test environment is the environment to which the sample or specimen is exposed during the entire test period. It is characterized by the specified values ??of one or two parameters of temperature and relative humidity, and maintaining them within a predetermined range. Note: The test is either carried out in the laboratory or in a special so-called "state conditioning box" or in a test chamber. The choice depends on the nature of the specimen or test piece and the conditions of the test itself. For example, if the performance of the specimen or specimen does not change significantly during the test, it is not necessary to strictly control the test environment. 3 Temperature and humidity for condition adjustment and testing
3.1 Standard environmental conditions (should be adopted whenever possible) temperature 23±2℃, relative humidity 50%±5%. 3.2 The standard temperature is 23±2℃, and the relative humidity is the ambient humidity. Note: For some tests, the temperature control range is more stringent. For example: when testing viscosity or consistency, the recommended control range is a maximum of ±0.5°C. 3.3 Other conditions
3.3.1 For certain areas where it is difficult to maintain the standard environmental conditions of Articles 3.1 and 3.2, and for non-arbitration purposes, other conditions may be specified, but they shall be noted in the test report.
3.3.2 For those environmental conditions where neither temperature nor relative humidity need to be controlled, if the temperature and humidity are known, they should be noted in the test report.
4 Condition adjustment
4.1 Condition adjustment time shall be specified by the specific test method considered, approved by the Ministry of Chemical Industry of the People's Republic of China on 1.988-04-19 and implemented on 1989-01-01||tt| |GB9278-88wwW.bzxz.Net
2 The relevant parts of the specimen and the instrument should be placed in a state-adjusted environment so that they can reach equilibrium with the environment as quickly as possible. The specimens should be protected from direct sunlight and the environment should be kept clean. The test panels should be separated from each other and from the walls of the condition conditioning box by a distance of at least 20 mm. 5 Test
Unless otherwise specified, the specimen shall be tested in the same environment as its condition. If the standard environmental conditions specified in Article 3.1 are used for condition adjustment and testing, the test report shall state: The condition is adjusted for hours under the standard environmental conditions consistent with this national standard, and then the test is carried out. If the standard environment specified in Article 3.1 is not used, conditions, and other conditions are selected, the test report should indicate the conditions used. Additional notes:
This standard is under the jurisdiction of the National Coatings and Pigments Standardization Technical Committee. This standard is drafted by the Coatings Industry Research Institute of the Ministry of Chemical Industry. The main drafter of this standard is Song Jianguo.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 6287-1992 Test method for reliability assessment of grain combine harvesters
- QB/T 2172-2001 Injection zipper
- GB/T 4789.33-2003 Microbiological examination of food hygiene Inspection of cereals, fruits and vegetables
- QB/T 2212.11-1996 Construction tools (brick and mortar) Pointed spade
- GBZ 12-2002 Diagnostic criteria for occupational chromium rhinitis
- JB/T 7974-1999 Cast iron plate
- GB/T 4329-2001 Dimensions and requirements for locking pins and spring pins for agricultural and forestry tractors and implements
- GB 15194-1994 Maximum residue limits of pesticides such as diffluanid in food
- GB/T 15362-1994 Test methods for rubber-tyred container gantry cranes
- GBZ/T 149-2002 Specification for health protection training for medical radiation workers
- QB/T 3562-1999 500ml crown-shaped bottle mouth liquor bottle
- GB/T 15018-1994 Precision alloy grades
- QB/T 2678-2004 Shoemaking machinery box-type wet heat setting machine
- GB 11297.9-1989 Test method for dielectric loss tangent tanδ of pyroelectric materials
- GB/T 5480.6-2004 Test methods for mineral wool and its products Part 6: Acidity coefficient
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:wymp4wang@gmail.com