
GB 4737-1984 Determination of permeability of daily-use pottery
time:
2024-08-05 05:47:25
- GB 4737-1984
- in force
Standard ID:
GB 4737-1984
Standard Name:
Determination of permeability of daily-use pottery
Chinese Name:
日用陶器渗透性测定方法
Standard category:
National Standard (GB)
-
Date of Release:
1984-11-02 -
Date of Implementation:
1985-08-01
Standard ICS number:
Glass and ceramics industry>>Ceramics>>81.060.20 Ceramic productsChina Standard Classification Number:
Light Industry, Cultural and Living Goods>>Daily Glass, Ceramics, Enamel, Plastic Products>>Y24 Daily Ceramics Products
Release date:
1984-11-02Review date:
2004-10-14Drafter:
Zhang Baoyu, Xu YuyangDrafting Organization:
Jiangsu Ceramics Research InstituteFocal point Organization:
Ceramics Research Institute of the Ministry of Light IndustryProposing Organization:
Ministry of Light Industry of the People's Republic of ChinaPublishing Department:
National Bureau of StandardsCompetent Authority:
China Light Industry Federation

Skip to download
Summary:
This standard is applicable to the determination of daily-use coarse pottery, fine pottery and fine pottery products with porosity greater than 3% and less than 30%. GB 4737-1984 Method for determination of permeability of daily-use pottery GB4737-1984 standard download decompression password: www.bzxz.net

Some standard content:
National Standard of the People's Republic of China
Test method for permeability of pottery ware of daily use
Staadard test method for permeability of water of pottery ware of daily use UC 666.64:539
GB 4737-84
This standard is used to test the permeability of daily use pottery, glazed pottery and fine ware with a pore size of less than 30%. Definition
The permeability of daily use pottery is the ability of daily use pottery products to penetrate water under a certain pressure. This method is expressed by the time when a sample of a certain thickness begins to penetrate water under a certain water pressure. 2 Equipment and use
2.1 Sampler: G-Tech 200 engineering diamond drill can be selected, with a hole diameter of 50mm. 2.2 Slicer.
2.a Heat-drying box.
2. Permeameter (Figure 1): It is packaged with SS-15 mortar gauge. The water outlet diameter of the measuring egg head is Φ5mm. The inner diameter of the sample die head (Figure 2) is 50mm, and the maximum sea pressure is 15krcm. 5
Figure! Permeameter
Vernier caliper: accuracy is 0.02mm.
2.6Second attack.
2.7Thermometer: t~C
National Standard 1984-11-02 Release
Figure 2 Die head
1985-08-01 Implementation
8Sample preparation
GB4787-B4
3.1 Take the bottom of six back-variety products and drill a cylindrical (sheet) sample with a diameter of 50mm to the upper block. For glazed products, use a flat grinder to grind off the interlayer and the interlayer. For sintered products without glaze, the surface should also be ground off until the surface of the sample is flat. The thickness deviation of the test blocks in the same group is less than 0.5mm for thin-walled products and less than 1mm for thick-walled products. The thickness depends on the product and is generally similar to the thickness of the product. When comparative measurements are required for different products, the thickness of the test blocks should be consistent, but one surface of the product should still be retained (only the glaze layer and the interlayer should be ground off). For large products that are not destructible, a sample should be made, and its thickness should be equal to the bottom of the product. The manufacturing process and conditions should be consistent with those of the product. Half of the sample must be 120gin×30cm, and then a drill is used to take samples and grind the glaze layer. 3.2 Rinse the ground sample with water, dry it in an electric drying oven at 105-110°C, take it out and store it in a desiccator for testing.
4 Determination steps
1 Fill the water container of the permeameter with water and check whether there is leakage in all parts of the instrument. After the instrument is normal, turn on the power switch to make the water pump work until water emerges from the small holes of each measuring head continuously, indicating that the water system is unobstructed. After the gas is driven, use a clean rag to remove the water from the measuring head.
.2 Take the sample to be tested and put it into the sample mold respectively, add a rubber ring (the hole diameter of the gasket is 35mm) or first put a 2mm diameter plasticine strip into the gap between the sample and the inner mold wall, and then separate the ring to seal the gap between the sample and the inner wall of the mold. The sample die head with the sample installed is screwed on the measuring fire of the instrument.
4.3 Rotate the pointer of the electric contact pressure gauge to the required pressure value, turn on the power to make the water pump work, and when the pressure reaches the adjusted value, the pump stops and the pressure is stabilized.
4.4 Close the valves of each measuring head respectively and start the stopwatch at the same time. At this time, the water pump will automatically start due to the pressure drop to maintain the original water pressure.
4.5 When tiny water drops or water marks appear on the surface of the test block, the stopwatches should be closed immediately, and the water pressure value of the test block, the time when penetration begins, and the condition of the test block surface when water penetrates are recorded. 4.6 After the test, turn off the power, open the reading door, drain the water in each pipe, turn the pressure gauge pointer to zero, take out the sample, and wipe off the water marks on the instrument.
5 Test results
5.1 The penetration time is expressed in minutes or seconds.
5.2 The determination of nesting is to take the arithmetic mean of the test blocks of the same level (6). The relative difference between the measured values of each test block should not be greater than 10%. Those with deviations exceeding 10% should be discarded.
5.3 Record and report As shown in Table 1 and Table 2: Original record of permeability determination of daily-use pottery
Chengxiang No.
Sample name
Water absorption
Sample thickness
Penetration pressure
kgf/cm\
Penetration time
Sample surface
Penetration condition
Determination period
Determination person
Sample unit price
Delivery product
Test items
Determination results
Supervisor:
Additional remarks:
Thickness of test block, mm
Determination pressure, kgf/cm*
Penetration interval, GBwwW.bzxz.Net
4737-84
Test report
Sample number
Report number
Report date
Tester:
Order:
This standard was proposed by the Ministry of Light Industry of the People's Republic of China and is under the technical supervision of the Ceramics Research Institute of the Ministry of Light Industry. This standard was drafted by the Jiangsu Ceramics Research Institute. The main drafters of this standard are Zhang Baoyu and Xu Yuyang. 54
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
Test method for permeability of pottery ware of daily use
Staadard test method for permeability of water of pottery ware of daily use UC 666.64:539
GB 4737-84
This standard is used to test the permeability of daily use pottery, glazed pottery and fine ware with a pore size of less than 30%. Definition
The permeability of daily use pottery is the ability of daily use pottery products to penetrate water under a certain pressure. This method is expressed by the time when a sample of a certain thickness begins to penetrate water under a certain water pressure. 2 Equipment and use
2.1 Sampler: G-Tech 200 engineering diamond drill can be selected, with a hole diameter of 50mm. 2.2 Slicer.
2.a Heat-drying box.
2. Permeameter (Figure 1): It is packaged with SS-15 mortar gauge. The water outlet diameter of the measuring egg head is Φ5mm. The inner diameter of the sample die head (Figure 2) is 50mm, and the maximum sea pressure is 15krcm. 5
Figure! Permeameter
Vernier caliper: accuracy is 0.02mm.
2.6Second attack.
2.7Thermometer: t~C
National Standard 1984-11-02 Release
Figure 2 Die head
1985-08-01 Implementation
8Sample preparation
GB4787-B4
3.1 Take the bottom of six back-variety products and drill a cylindrical (sheet) sample with a diameter of 50mm to the upper block. For glazed products, use a flat grinder to grind off the interlayer and the interlayer. For sintered products without glaze, the surface should also be ground off until the surface of the sample is flat. The thickness deviation of the test blocks in the same group is less than 0.5mm for thin-walled products and less than 1mm for thick-walled products. The thickness depends on the product and is generally similar to the thickness of the product. When comparative measurements are required for different products, the thickness of the test blocks should be consistent, but one surface of the product should still be retained (only the glaze layer and the interlayer should be ground off). For large products that are not destructible, a sample should be made, and its thickness should be equal to the bottom of the product. The manufacturing process and conditions should be consistent with those of the product. Half of the sample must be 120gin×30cm, and then a drill is used to take samples and grind the glaze layer. 3.2 Rinse the ground sample with water, dry it in an electric drying oven at 105-110°C, take it out and store it in a desiccator for testing.
4 Determination steps
1 Fill the water container of the permeameter with water and check whether there is leakage in all parts of the instrument. After the instrument is normal, turn on the power switch to make the water pump work until water emerges from the small holes of each measuring head continuously, indicating that the water system is unobstructed. After the gas is driven, use a clean rag to remove the water from the measuring head.
.2 Take the sample to be tested and put it into the sample mold respectively, add a rubber ring (the hole diameter of the gasket is 35mm) or first put a 2mm diameter plasticine strip into the gap between the sample and the inner mold wall, and then separate the ring to seal the gap between the sample and the inner wall of the mold. The sample die head with the sample installed is screwed on the measuring fire of the instrument.
4.3 Rotate the pointer of the electric contact pressure gauge to the required pressure value, turn on the power to make the water pump work, and when the pressure reaches the adjusted value, the pump stops and the pressure is stabilized.
4.4 Close the valves of each measuring head respectively and start the stopwatch at the same time. At this time, the water pump will automatically start due to the pressure drop to maintain the original water pressure.
4.5 When tiny water drops or water marks appear on the surface of the test block, the stopwatches should be closed immediately, and the water pressure value of the test block, the time when penetration begins, and the condition of the test block surface when water penetrates are recorded. 4.6 After the test, turn off the power, open the reading door, drain the water in each pipe, turn the pressure gauge pointer to zero, take out the sample, and wipe off the water marks on the instrument.
5 Test results
5.1 The penetration time is expressed in minutes or seconds.
5.2 The determination of nesting is to take the arithmetic mean of the test blocks of the same level (6). The relative difference between the measured values of each test block should not be greater than 10%. Those with deviations exceeding 10% should be discarded.
5.3 Record and report As shown in Table 1 and Table 2: Original record of permeability determination of daily-use pottery
Chengxiang No.
Sample name
Water absorption
Sample thickness
Penetration pressure
kgf/cm\
Penetration time
Sample surface
Penetration condition
Determination period
Determination person
Sample unit price
Delivery product
Test items
Determination results
Supervisor:
Additional remarks:
Thickness of test block, mm
Determination pressure, kgf/cm*
Penetration interval, GBwwW.bzxz.Net
4737-84
Test report
Sample number
Report number
Report date
Tester:
Order:
This standard was proposed by the Ministry of Light Industry of the People's Republic of China and is under the technical supervision of the Ceramics Research Institute of the Ministry of Light Industry. This standard was drafted by the Jiangsu Ceramics Research Institute. The main drafters of this standard are Zhang Baoyu and Xu Yuyang. 54
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- GB/T 29881-2013 Test method for classification of hazardous materials—Hydrobiology toxicity test
- HG/T 20666-1999 Design code for electrical power in corrosive environments of chemical enterprises (with clause explanation)
- GB/T 15521-1995 Digital Audio Cassette System (DAT) for broadcasting - Format and classification characteristics
- GBJ 128-1990 Specification for the construction and acceptance of vertical cylindrical steel welded oil tanks GBJ128-90
- GBJ 119-1988 Technical specification for application of concrete admixtures GBJ119-88
- GBJ 1-1986 Unified standard for building architectural drawings GBJ1-86
- HG/T 2971-1999 Test method for industrial methylamine aqueous solution
- GB/T 29115-2012 Evaluating guide for raw material saving of industrial enterprises
- GB/T 15072.5-1994 Chemical analysis methods for precious metals and their alloys - Determination of silver content in gold and palladium alloys
- GB/T 13217.1-1991 Test method for colour of plastics gravure printing inks
- HG/T 20519.34-1992 Legends for equipment and piping layout drawings
- HG/T 2245-1991 Various colors of nitro pencil lacquers
- GBJ 98-1987 Fire protection code for civil air defense engineering design GBJ98-87
- JB/T 7617-1994 Sulfur hexafluoride tank type gapless metal oxide arrester
- HG/T 2578-1994 Rubber shield for automobile hydraulic brake cylinder
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:bzxznet@163.com