Determination of silicon oxide in high purity arenaceous quartz
time:
2024-07-05 09:27:35
- SJ 3228.4-1989
- Abolished
Standard ID:
SJ 3228.4-1989
Standard Name:
Determination of silicon oxide in high purity arenaceous quartz
Chinese Name:
高纯石英砂二氧化硅的测定
Standard category:
Electronic Industry Standard (SJ)
-
Date of Release:
1989-03-20 -
Date of Implementation:
1989-03-25 -
Date of Expiration:
2016-06-01
China Standard Classification Number:
General>>Standardization Management and General Provisions>>A01 Technical Management
alternative situation:
Replaced by SJ/T 3228.4-2016
Drafter:
Shen Xuebin, Liu ChengjunDrafting Organization:
The 18th Research Institute of the Ministry of Machinery and Electronics IndustryProposing Organization:
Electronic Standardization Institute of the Ministry of Machinery and Electronics IndustryPublishing Department:
Ministry of Machinery and Electronics Industry of the People's Republic of China

Skip to download
Summary:
This standard specifies the determination of silicon dioxide content in high-purity quartz sand. This standard is applicable to the analysis of various grades of high-purity quartz sand. SJ 3228.4-1989 Determination of silicon dioxide in high-purity quartz sand SJ3228.4-1989 Standard download decompression password: www.bzxz.net
This standard specifies the determination of silicon dioxide content in high-purity quartz sand. This standard is applicable to the analysis of various grades of high-purity quartz sand.
This standard specifies the determination of silicon dioxide content in high-purity quartz sand. This standard is applicable to the analysis of various grades of high-purity quartz sand.

Some standard content:
Standard of the Ministry of Machinery and Electronics Industry of the People's Republic of China Determination of silicon dioxide in high-purity quartz sand
1 Subject content and scope of application
1.1 Subject content
This standard specifies the determination of silicon dioxide content in high-purity quartz sand1.2 Scope of applicationbzxz.net
This standard is applicable to various grades of high-purity quartz sand. Reference standard
SJI3228.2—99 General rules for analysis of high-purity quartz sand. 3 Method summary
SJ3228.4—89
The sample is treated with sulfuric acid and hydrofluoric acid to volatilize silicon dioxide in the form of silicon tetrafluoride. The amount volatilized is the content of silicon dioxide.
4 Reagents
4.1 Hydrofluoric acid: 40% high-grade pure
4.2 Sulfuric acid: 11.
5 Analysis steps
Accurately weigh 1g of the sample after ignition loss, place it in a platinum crucible with constant weight, add a few drops of water to wet the sample, then add 5 drops of 1:1 sulfuric acid and 20ml hydrofluoric acid, heat to dissolve, evaporate to dryness, and move into a muffle furnace. Ignite at 950~1000℃ for 30min, move to a desiccator to cool to room temperature and weigh, and repeat ignition until constant weight. 6 Calculation
Si0(%)=m1=m=×100
Where: m1——the amount of the sample after ignition loss. gm2The amount of the crucible and sample residue after treatment with hydrofluoric acid. gm-—the amount of the sample after ignition loss. g.
Approved by the Ministry of Machinery and Electronics Industry of the People's Republic of China on March 20, 1989, and implemented on March 25, 1989
Measurement accuracy
The relative standard deviation is less than 5%.
Additional Notes:
SJ3228.4-89
This standard was proposed by the Electronic Standardization Institute of the Ministry of Machinery and Electronics Industry. This standard was drafted by Jiangsu Xinyi Ahu Stone Powder Factory and the Electronic Standardization Institute of the Ministry of Machinery and Electronics Industry. The main drafters of this standard are Shen Xuebin and Liu Chenggou. 2
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
1 Subject content and scope of application
1.1 Subject content
This standard specifies the determination of silicon dioxide content in high-purity quartz sand1.2 Scope of applicationbzxz.net
This standard is applicable to various grades of high-purity quartz sand. Reference standard
SJI3228.2—99 General rules for analysis of high-purity quartz sand. 3 Method summary
SJ3228.4—89
The sample is treated with sulfuric acid and hydrofluoric acid to volatilize silicon dioxide in the form of silicon tetrafluoride. The amount volatilized is the content of silicon dioxide.
4 Reagents
4.1 Hydrofluoric acid: 40% high-grade pure
4.2 Sulfuric acid: 11.
5 Analysis steps
Accurately weigh 1g of the sample after ignition loss, place it in a platinum crucible with constant weight, add a few drops of water to wet the sample, then add 5 drops of 1:1 sulfuric acid and 20ml hydrofluoric acid, heat to dissolve, evaporate to dryness, and move into a muffle furnace. Ignite at 950~1000℃ for 30min, move to a desiccator to cool to room temperature and weigh, and repeat ignition until constant weight. 6 Calculation
Si0(%)=m1=m=×100
Where: m1——the amount of the sample after ignition loss. gm2The amount of the crucible and sample residue after treatment with hydrofluoric acid. gm-—the amount of the sample after ignition loss. g.
Approved by the Ministry of Machinery and Electronics Industry of the People's Republic of China on March 20, 1989, and implemented on March 25, 1989
Measurement accuracy
The relative standard deviation is less than 5%.
Additional Notes:
SJ3228.4-89
This standard was proposed by the Electronic Standardization Institute of the Ministry of Machinery and Electronics Industry. This standard was drafted by Jiangsu Xinyi Ahu Stone Powder Factory and the Electronic Standardization Institute of the Ministry of Machinery and Electronics Industry. The main drafters of this standard are Shen Xuebin and Liu Chenggou. 2
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- JB/T 8074.2-1999 Technical requirements for manual self-centering chucks for machine tools
- GBZ 68-2002 Diagnostic criteria for occupational benzene poisoning
- GB/T 39995-2021 Determination of sterols
- GB 13594-1992 Performance requirements and test methods for automotive anti-lock braking systems
- GB/T 5009.47-2003 Analytical methods for hygienic standards of eggs and egg products
- QB/T 1440-1992 Business Card Book
- GB/T 15534-1995 Information processing system database language NDL
- GB/T 15399-1994 Determination of sulfur-containing amino acids in feeds--Ion exchange chromatography
- GB/T 15555.6-1995 Determination of total chromium in solid wastes - Direct inhalation flame atomic absorption spectrophotometry
- JB/T 3341-1999 Basic parameters of pallet stacker
- GB/T 13546-1992 Rectifying sampling procedures and tables for inspections by attributes
- GB/T 8151.2-2000 Chemical analysis methods for zinc concentrates - Determination of sulfur content
- JB/T 8523-1997 Technical requirements for explosion-proof ventilators
- GB/T 24420-2009 Supply chain risk management guideline
- GB/T 18894-2002 STANDARDs of electronic records filing and management
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]