GB 19079.7-2005 Opening conditions and technical requirements for sports venues Part 7: Skating venues
time:
2024-08-05 21:04:16
- GB 19079.7-2005
- in force
Standard ID:
GB 19079.7-2005
Standard Name:
Opening conditions and technical requirements for sports venues Part 7: Skating venues
Chinese Name:
体育场所开放条件与技术要求 第7部分:滑冰场所
Standard category:
National Standard (GB)
-
Date of Release:
2005-01-24 -
Date of Implementation:
2005-06-01
Standard ICS number:
Household and commercial equipment, recreation, sports >> 97.220 Sports equipment and facilitiesChina Standard Classification Number:
Light Industry, Culture and Living Goods>>Culture, Education, Sports and Entertainment Goods>>Y55 Sports Facilities and Equipment
publishing house:
China Standards PressISBN:
155066.1-22405Publication date:
2005-06-01Plan number:
20030559-Q-451
Release date:
2005-01-24Drafter:
Li Shihua, Chen Xueling, An Zhijian, Men Chuansheng, Hao Qingwei, Shi Chunjian, Li Zhi, Wang RonghuiDrafting Organization:
Shenyang Sport University, Winter Sports Management Center of the State Sports General AdministrationFocal point Organization:
Economic Department of the State Sports General AdministrationProposing Organization:
State Sports General AdministrationPublishing Department:
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Standardization Administration of ChinaCompetent Authority:
State Sports General Administration

Skip to download
Summary:
This part of GB 19079 stipulates the basic conditions and basic technical requirements for the opening of skating venues. This part applies to all types of skating venues open to the public. GB 19079.7-2005 Opening conditions and technical requirements for sports venues Part 7: Skating venues GB19079.7-2005 Standard download decompression password: www.bzxz.net

Some standard content:
ICS 97.220
National Standard of the People's Republic of ChinawwW.bzxz.Net
GB 19079.7—2005
Operation conditions and technical requirements for gymnasium and playgroundPart 7: Skating place
2005-01-24 Issued
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Standardization Administration
com2005-06-01 Implementation
(B{9079&Opening conditions and technical requirements for sports venues are divided into the following parts: Part 1: Swimming places:
Part 2. Karting places
Part 3: Bungee jumping places;
Part 4: Rock climbing places:
Part 5: Wheelchair places;
Part 6: Slide station places;
Part 7: Skating places;|| tt||Part 8: Shooting sites:
Part 9: Archery sites:
·Part 1· Diving sites;
-Part 11: Drifting sites:
--Part 12: Paragliding sites:
-Part 13: Hot air balloon sites:
-Part 14: Powered paragliding sites:
This part is Part 7 of GB1079, and all the contents of this part are mandatory. This part is proposed by the State Sports General Administration:
This part is interpreted by the Economic Department of the State Sports General Administration, and the drafting units of this part are: Shenfu Sports College, Winter Sports Management Center of the State Sports General Administration GB 19079.7—2005
Drafters of this part: Li Sanghua, Chen Leiling, An Zhijin, Men Chuansheng, Hao Qingwei, Shi Chunjian, Li Zhi, Wang Rongbian, 1 Scope
Opening conditions and technical requirements for sports venues
Part 7: Ice skating venues
This part of GB19079 specifies the basic conditions and basic technical requirements for the opening of ice skating venues. This part applies to all types of ice skating venues open to the public. 2 Normative references
GB19079.7—2005
The following documents have become the terms of this standard through reference in this standard, which are dated references: Some amendments (excluding errata) or revisions are not applicable to this standard. However, the parties that reach an agreement based on this standard are encouraged to study whether the latest versions of these documents can be used. The latest versions of all undated referenced documents are applicable to this standard. GB9664 Hygiene standard for cultural and entertainment venues
GB9668 Hygiene standard for gymnasiums
GB3095 Ambient air quality standard
GB/T17093 Hygiene standard for total number of bacteria in indoor air G3/T10001, 1 Public information graphic symbols for signs Part 1: General symbols 3 Terms and definitions
The following terms and definitions apply to this part of (:R1007 3. 1
skatingplace
Skating venue
A place where people can carry out skating training, competition, fitness and entertainment, etc. It includes: indoor skating venues and outdoor ice-clearing venues,
Ice equipment
Equipment that skaters need to carry out skating activities, including ice skates, skates, protective gear, etc. 3.3
Skating instructors are those who teach the theory and skills of skating. 4 Qualifications of practitioners
Those who are responsible for skating techniques, hostage guidance, security guards, etc. must hold relevant professional qualification certificates before they can take up their posts. 5 Conditions of venues, facilities and equipment
5. 1 Indoor skating venues
5.1.1 Venue
5.1. 1 The area of the venue shall not be less than 50\
5.1.1.2 The thickness of the ice shall not be less than 3mm, and the temperature of the ice surface shall not be higher than -1℃. 5.1.1.3 The ice surface shall be smooth and flat, and there shall be no cracks that affect walking. 5.1.1.4 The horizontal illumination of indoor skating venues shall not be less than 1001x: 5.1.2 Facilities and Equipment 5.1.2.1 Anti-slip walkways, chairs and handrails shall be provided. 5.1.2.2 Safety protection facilities with a height of not less than 1m shall be provided around the venue. 5.1.2.3 Skating equipment and protective gear shall be provided. 5.1.2.4 The facilities and equipment of skating venues shall obtain product inspection certificates issued by professional and technical organizations that meet the statutory requirements. 5.2 Outdoor Skating Venues 5.2.1 Venues 5.2.1.1 The area of the venue shall not be less than 2000) u. 5.2.1.2 The illumination of open water at night shall not be less than 2001x. 5.2.2 Facilities and Equipment
5.2.2.1 There are clear and conspicuous warning signs and safety facilities for dangerous areas. 5.2.2.2 There are skating equipment and protective gear.
5.2.2.3 The facilities and equipment of the skating venue should obtain the product inspection certificate issued by the professional technical organization that meets the statutory conditions. 5.3 Auxiliary Facilities
5.3.1 There are men's and women's changing rooms, and there are no facilities for storing clothes. 5.3.2 There are men's and women's rooms.
5.3.3 There are broadcasting and communication equipment,
5.3.4 Indoor swimming pools have emergency evacuation passages. 5.3.5 Public signs should comply with the requirements of GB/T10001.1: 6 Health and environmental management requirements
6.1 The environmental hygiene of the skating venue should comply with the requirements of GB9664 and GB9666% 6.2 The outdoor air of the skating venue should comply with the requirements of GB3095, 6.3 The air inside the skating venue should comply with the requirements of GB/T 17093. 7 Safety assurance
7.1 There should be "Instructions for Skating Personnel" and safety warnings in a conspicuous position, 7.2 First aid medicines and equipment should be placed in a conspicuous position for easy access. 7.3 There should be obvious signs on the uniforms of various personnel. 7.4 There should be a complete system of public security, safety rescue, equipment maintenance and a responsibility system for personnel service positions. com
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
National Standard of the People's Republic of ChinawwW.bzxz.Net
GB 19079.7—2005
Operation conditions and technical requirements for gymnasium and playgroundPart 7: Skating place
2005-01-24 Issued
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Standardization Administration
com2005-06-01 Implementation
(B{9079&Opening conditions and technical requirements for sports venues are divided into the following parts: Part 1: Swimming places:
Part 2. Karting places
Part 3: Bungee jumping places;
Part 4: Rock climbing places:
Part 5: Wheelchair places;
Part 6: Slide station places;
Part 7: Skating places;|| tt||Part 8: Shooting sites:
Part 9: Archery sites:
·Part 1· Diving sites;
-Part 11: Drifting sites:
--Part 12: Paragliding sites:
-Part 13: Hot air balloon sites:
-Part 14: Powered paragliding sites:
This part is Part 7 of GB1079, and all the contents of this part are mandatory. This part is proposed by the State Sports General Administration:
This part is interpreted by the Economic Department of the State Sports General Administration, and the drafting units of this part are: Shenfu Sports College, Winter Sports Management Center of the State Sports General Administration GB 19079.7—2005
Drafters of this part: Li Sanghua, Chen Leiling, An Zhijin, Men Chuansheng, Hao Qingwei, Shi Chunjian, Li Zhi, Wang Rongbian, 1 Scope
Opening conditions and technical requirements for sports venues
Part 7: Ice skating venues
This part of GB19079 specifies the basic conditions and basic technical requirements for the opening of ice skating venues. This part applies to all types of ice skating venues open to the public. 2 Normative references
GB19079.7—2005
The following documents have become the terms of this standard through reference in this standard, which are dated references: Some amendments (excluding errata) or revisions are not applicable to this standard. However, the parties that reach an agreement based on this standard are encouraged to study whether the latest versions of these documents can be used. The latest versions of all undated referenced documents are applicable to this standard. GB9664 Hygiene standard for cultural and entertainment venues
GB9668 Hygiene standard for gymnasiums
GB3095 Ambient air quality standard
GB/T17093 Hygiene standard for total number of bacteria in indoor air G3/T10001, 1 Public information graphic symbols for signs Part 1: General symbols 3 Terms and definitions
The following terms and definitions apply to this part of (:R1007 3. 1
skatingplace
Skating venue
A place where people can carry out skating training, competition, fitness and entertainment, etc. It includes: indoor skating venues and outdoor ice-clearing venues,
Ice equipment
Equipment that skaters need to carry out skating activities, including ice skates, skates, protective gear, etc. 3.3
Skating instructors are those who teach the theory and skills of skating. 4 Qualifications of practitioners
Those who are responsible for skating techniques, hostage guidance, security guards, etc. must hold relevant professional qualification certificates before they can take up their posts. 5 Conditions of venues, facilities and equipment
5. 1 Indoor skating venues
5.1.1 Venue
5.1. 1 The area of the venue shall not be less than 50\
5.1.1.2 The thickness of the ice shall not be less than 3mm, and the temperature of the ice surface shall not be higher than -1℃. 5.1.1.3 The ice surface shall be smooth and flat, and there shall be no cracks that affect walking. 5.1.1.4 The horizontal illumination of indoor skating venues shall not be less than 1001x: 5.1.2 Facilities and Equipment 5.1.2.1 Anti-slip walkways, chairs and handrails shall be provided. 5.1.2.2 Safety protection facilities with a height of not less than 1m shall be provided around the venue. 5.1.2.3 Skating equipment and protective gear shall be provided. 5.1.2.4 The facilities and equipment of skating venues shall obtain product inspection certificates issued by professional and technical organizations that meet the statutory requirements. 5.2 Outdoor Skating Venues 5.2.1 Venues 5.2.1.1 The area of the venue shall not be less than 2000) u. 5.2.1.2 The illumination of open water at night shall not be less than 2001x. 5.2.2 Facilities and Equipment
5.2.2.1 There are clear and conspicuous warning signs and safety facilities for dangerous areas. 5.2.2.2 There are skating equipment and protective gear.
5.2.2.3 The facilities and equipment of the skating venue should obtain the product inspection certificate issued by the professional technical organization that meets the statutory conditions. 5.3 Auxiliary Facilities
5.3.1 There are men's and women's changing rooms, and there are no facilities for storing clothes. 5.3.2 There are men's and women's rooms.
5.3.3 There are broadcasting and communication equipment,
5.3.4 Indoor swimming pools have emergency evacuation passages. 5.3.5 Public signs should comply with the requirements of GB/T10001.1: 6 Health and environmental management requirements
6.1 The environmental hygiene of the skating venue should comply with the requirements of GB9664 and GB9666% 6.2 The outdoor air of the skating venue should comply with the requirements of GB3095, 6.3 The air inside the skating venue should comply with the requirements of GB/T 17093. 7 Safety assurance
7.1 There should be "Instructions for Skating Personnel" and safety warnings in a conspicuous position, 7.2 First aid medicines and equipment should be placed in a conspicuous position for easy access. 7.3 There should be obvious signs on the uniforms of various personnel. 7.4 There should be a complete system of public security, safety rescue, equipment maintenance and a responsibility system for personnel service positions. com
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.
- Recommended standards
- SY/T 6515-2001 Ignition characteristics of hydrocarbon gases in open hot surface environments
- JB/T 9885-1999 Technical requirements for hydraulic slides of modular machine tools
- JB/T 8121-1999 High-pressure fuel pipe assembly for diesel engine fuel injection pump test bench
- JJG 56-2000 Verification Regulation of Toolmakers Microscope
- QB/T 1476-2004 Fishing rod
- GB/T 3286.7-1998 Chemical analysis methods for limestone and dolomite - Determination of sulfur content
- GB/T 4549.7-1984 Terminology of heating, ventilation and air conditioning equipment for railway vehicles
- GB 12141-1989 Safety specification for freight aerial ropeways
- GB 8139-1987 Dewaxed shellac sheets, decolorized shellac sheets and decolorized dewaxed shellac sheets
- GA 411-2003 Chemical oxygen fire fighting self-rescue breathing apparatus
- JB/T 7929-1999 Cleanliness of gear transmission
- JB/T 5266-1991 Indirect resistance furnace RY series electric heating bath furnace
- GB/T 18832-2002 Box pallet and post pallet
- JGJ/T 111-1998 Technical Specification for Building and Municipal Precipitation Engineering JGJ/T111-98
- GB 8410-1994 Combustion characteristics of automotive interior materials
Please remember: "bzxz.net" is the combination of the first letters of the Chinese pinyin of the four Chinese characters "standard download" and the international top-level domain name ".net". ©2024 Standard download websitewww.bzxz.net Mail:[email protected]