AS 1824.2-1985 Insulation coordination - phase-to-
绝缘配合(相对地和相间,1kV以上)第2部分——应用指南
AS 1824.2-1985 Insulation coordination - phase-to-earth and phase-to-phase, above 1 kV - - Application guide
Insulation Coordination (Phase-to-Earth and Phase-to-Phase, Above 1 kV) Part 2—Application Guide
标准信息
STANDARD INFORMATION- 标准编号
- AS 1824.2-1985 Insulation coordination - phase-to-
- 所属分类
- AS 澳大利亚标准
- 发布机构
- Standards Australia
- 版本年份
- 1985
- 文件语言
- 英语
- 文件格式
- 文件页数
- 6 页
- 文件大小
- 368.11 KB
中文名称为参考译名,文件语言以原文为准。
· 更新:
标准简介
OVERVIEW中文简介
该标准提供了1kV以上电力系统中绝缘配合的应用指南,涵盖相地及相间绝缘。它详细阐述了运行中的电压应力、绝缘耐受水平以及保护设备的选择,旨在指导如何协调电压应力与绝缘耐受能力。
English summary
This standard provides an application guide for insulation coordination in power systems above 1 kV, covering phase-to-earth and phase-to-phase insulation. It details voltage stresses in service, insulation withstand levels, and the selection of protective devices to coordinate voltage stresses with insulation capabilities.
以上为根据文件整理的内容简介。
相关标签
标准内容预览
DOCUMENT PREVIEWLICENCE
for
Licensee:
Date:
Conditions of use: Click here for full conditions of Licence
WEB LINKS
- Check if this document is current
- Find similar documents
- StandardsWatch (info and login)
- Visit our website
International Standards on-line at www.saiglobal.com/shop
1
Australian Standard®
INSULATION COORDINATION (PHASE-TO-EARTH AND PHASE-TO-PHASE, ABOVE 1 kV)
Part 2—APPLICATION GUIDE
2
This Australian standard was prepared by Committee EL/7, Power Switchgear. It was approved on behalf of the Council of the Standards Association of Australia on 16 January 1985 and published on 10 May 1985.
The following interests are represented on Committee EL/7:
Australian-British Chamber of Commerce
Australian Electrical and Electronic Manufacturers Association
Confederation of Australian Industry
Electricity Supply Association of Australia
Institution of Engineers, Australia
Railways of Australia Committee
Testing authorities
Review of Australian Standards. To keep abreast of progress in industry, Australian Standards are subject to periodic review and are kept up to date by the issue of amendments or new editions as necessary. It is important therefore that Standards users ensure that they are in possession of the latest edition, and any amendments thereto.
Full details of all Australian Standards and related publications will be found in the Standards Australia Catalogue of Publications; this information is supplemented each month by the magazine 'The Australian Standard', which subscribing members receive, and which gives details of new publications, new editions and amendments, and of withdrawn Standards.
Suggestions for improvements to Australian Standards, addressed to the head office of Standards Australia, are welcomed. Notification of any inaccuracy or ambiguity found in an Australian Standard should be made without delay in order that the matter may be investigated and appropriate action taken.
This standard was issued in draft form for comment as DR 84030.
2 Scope
This Australian Standard deals with the description and measurement of environmental noise in general.
2.1 General
The standard applies to situations where the effect of environmental noise on people is to be assessed.
| Location | Level |
|---|---|
| Residential | 45 dB |
3
AS 1824.2—1985
Australian Standard®
INSULATION COORDINATION (PHASE-TO-EARTH AND PHASE-TO-PHASE, ABOVE 1 kV)
Part 2—APPLICATION GUIDE
| First published | 1978 |
| Second edition | 1985 |
PUBLISHED BY STANDARDS AUSTRALIA
(STANDARDS ASSOCIATION OF AUSTRALIA)
1 THE CRESCENT, HOMEBUSH, NSW 2140
ISBN 0 7262 3693 4
4
PREFACE
This standard was prepared by the Association's Committee on Power Switchgear as a new edition of AS 1824, Part 2—1978.
It provides guidance in the application of AS 1824, Part 1.
This standard is based on IEC 71-2(1976) and IEC 71-3(1982)—Insulation Coordination, Part 2: Application Guide; and Part 3: Phase-to-phase insulation coordination, Principles, Rules and Application Guide. Acknowledgement is made of the assistance received from the above standards.
While this standard is technically similar to IEC 71-2 and IEC 71-3, it has been drafted so that it eliminates those portions of the IEC texts which it was felt did not contribute to the understanding or application of AS 1824, Part 1, or which would be more appropriately located in a textbook. Additionally, Appendix C of IEC 72-2 (Statistical Evaluation of the Protective Effect of Spark Gaps) is not included, as such an evaluation is not appropriate to a standard on insulation coordination.
Where this edition of this standard differs technically from AS 1824, Part 2—1978 and IEC 71-3 by amended or additional text, a rule is shown in the margin against the table, clause or part thereof affected and such deviations are summarized in the Annex.
© Copyright — STANDARDS AUSTRALIA
Users of Standards are reminded that copyright subsists in all Standards Australia publications and software. Except where the Copyright Act allows and except where provided for below no publications or software produced by Standards Australia may be reproduced, stored in a retrieval system in any form or transmitted by any means without prior permission in writing from Standards Australia. Permission may be conditional on an appropriate royalty payment. Requests for permission and information on commercial software royalties should be directed to the head office of Standards Australia.
Standards Australia will permit up to 10 percent of the technical content pages of a Standard to be copied for use exclusively in-house by purchasers of the Standard without payment of a royalty or advice to Standards Australia.
Standards Australia will also permit the inclusion of its copyright material in computer software programs for no royalty payment provided such programs are used exclusively in-house by the creators of the programs.
Care should be taken to ensure that material used is from the current edition of the Standard and that it is updated whenever the Standard is amended or revised. The number and date of the Standard should therefore be clearly identified.
The use of material in print form or in computer software programs to be used commercially, with or without payment, or in commercial contracts is subject to the payment of a royalty. This policy may be varied by Standards Australia at any time.
5
CONTENTS
| Page | ||
|---|---|---|
| SECTION 1. | SCOPE AND GENERAL | |
| 1.1 | Scope | 5 |
| 1.2 | Object | 5 |
| 1.3 | Referenced Documents | 5 |
| 1.4 | Definitions | 5 |
| SECTION 2. | VOLTAGE STRESSES IN SERVICE | |
| 2.1 | General | 6 |
| 2.2 | Power-frequency Voltages | 6 |
| 2.3 | Temporary Overvoltages | 6 |
| 2.4 | Switching Overvoltages | 7 |
| 2.5 | Lightning Overvoltages | 8 |
| 2.6 | Determination of the Expected Overvoltage Level | 8 |
| SECTION 3. | INSULATION WITHSTAND | |
| 3.1 | General | 11 |
| 3.2 | Insulation Behaviour at Power Frequency Voltage and Temporary Overvoltages | 11 |
| 3.3 | Probability of Disruptive Discharge Under Impulse Voltages | 11 |
| 3.4 | Equipment with Windings | 11 |
| SECTION 4. | PROTECTIVE DEVICES | |
| 4.1 | General | 13 |
| 4.2 | Non-linear Resistor-type Surge Diverters | 13 |
| 4.3 | Spark Gaps | 13 |
| 4.4 | Application of Different Protective Devices | 14 |
| SECTION 5. | COORDINATION BETWEEN STRESSES AND WITHSTAND LEVELS—CONSIDERATIONS COMMON TO VOLTAGE RANGES, A, B AND C | |
| 5.1 | General | 15 |
| 5.2 | Pollution | 15 |
| 5.3 | Ageing | 15 |
| SECTION 6. | COORDINATION BETWEEN STRESSES AND WITHSTAND IN VOLTAGE RANGE A | |
| 6.1 | Selection of the Rated Short Duration Power-frequency Withstand Voltage | 16 |
| 6.2 | Selection of the Rated Lightning Impulse Withstand Voltage | 16 |
| SECTION 7. | COORDINATION BETWEEN STRESSES AND WITHSTAND IN VOLTAGE RANGE B | |
| 7.1 | General | 20 |
| 7.2 | Selection of Rated Power-frequency Withstand Voltage | 20 |
| 7.3 | Selection of Rated Lightning Impulse Withstand Voltage | 20 |
| SECTION 8. | COORDINATION BETWEEN STRESSES AND WITHSTAND IN VOLTAGE RANGE C | |
| 8.1 | Insulation Design to Power Frequency Voltage and Temporary Overvoltages | 21 |
| 8.2 | Insulation Design to Switching and Lightning Overvoltages | 21 |
| 8.3 | Insulation Design and Coordination Procedures | 22 |
| APPENDICES | ||
| A | Surge Transference Through Transformers | 30 |
| B | Validity of Tests Described in Part 1 | 35 |