IEC 60099-5 A1 1999 surge arresters
浪涌保护器 - 第5部分:选择和应用建议 - 第1节:总则
IEC 60099-5 A1 1999 surge arresters
Surge arresters – Part 5: Selection and application recommendations – Section 1: General
标准信息
STANDARD INFORMATION- 标准编号
- IEC 60099-5 A1 1999 surge arresters
- 所属分类
- IEC 国际电工标准
- 发布机构
- IEC
- 版本年份
- 1999
- 文件语言
- 英语
- 文件格式
- 文件页数
- 6 页
- 文件大小
- 637.55 KB
中文名称为参考译名,文件语言以原文为准。
· 更新:
标准简介
OVERVIEW中文简介
该标准是IEC 60099-5的第一修正案,主要更新了关于浪涌保护器(特别是金属氧化物避雷器)在运行状态下的诊断指标章节。它详细描述了用于监测避雷器绝缘性能劣化的各种诊断方法,包括故障指示器、断开器、浪涌计数器以及泄漏电流测量技术。标准重点阐述了在线和离线泄漏电流测量的原理、优缺点及具体实施细节,旨在为电力系统中避雷器的状态监测和维护提供指导。
English summary
This standard is Amendment 1 to IEC 60099-5, primarily updating the section on diagnostic indicators for metal-oxide surge arresters in service. It details various diagnostic methods for monitoring the deterioration of insulating properties, including fault indicators, disconnectors, surge counters, and leakage current measurement techniques. The document focuses on the principles, advantages, and disadvantages of on-line and off-line leakage current measurements, providing guidance for the condition monitoring and maintenance of surge arresters in power systems.
以上为根据文件整理的内容简介。
相关标签
标准内容预览
DOCUMENT PREVIEW6.1.6.1.2 Resistive leakage current
There is no evidence that the capacitive current would change significantly due to deterioration of the voltage-current characteristic of the non-linear metal-oxide resistors. Therefore, it is unlikely that measurements of capacitive current can reliably indicate the condition of metal-oxide arresters.
At given values of voltage and temperature, the resistive component of the leakage current is a sensitive indicator of changes in the voltage-current characteristic of non-linear metal-oxide resistors. The resistive current can, therefore, be used as a tool for diagnostic indication of changes in the condition of metal-oxide arresters in service. Typical resistive and capacitive voltage-current characteristics for a.c. voltages are shown in figure 5. For comparison, typical characteristics for d.c. voltages are also shown in figure 5.
Figure 5 – Typical voltage-current characteristics for non-linear metal-oxide resistors
The resistive component under a.c. voltage is defined as the current level at the instant of voltage maximum (dU/dt = 0), as indicated in figure 3. The resistive leakage current of a non-linear metal-oxide resistor is in the order of 5 % to 20 % of the capacitive current under normal operating conditions, corresponding to about 10 µA to 600 µA peak resistive current at a temperature of +20 °C.
In the leakage current region, the resistive current depends on the voltage and temperature. Typical values of voltage and temperature dependencies under a.c. voltage are indicated in figures 6 and 7, normalized to Uc and at +20 °C, respectively.
6
2 Scope
2
NORME INTERNATIONALE INTERNATIONAL STANDARD МЕЖДУНАРОДНЫЙ СТАНДАРТ
|
NORME INTERNATIONALE INTERNATIONAL STANDARD МЕЖДУНАРОДНЫЙ СТАНДАРТ |
CEI IEC 50(426) Première édition First edition 1990-10 Vocabulaire Electrotechnique InternationalChapitre 426 : Matériel électrique pour atmosphères explosives International Electrotechnical VocabularyChapter 426 : Electrical apparatus for explosive atmospheres Международный Электротехнический СловарьГлава 426 : Электрооборудование для взрывоопасных сред © CEI 1990 Droits de reproduction réservés - Copyright - all rights reserved - Право издания охраняется законом Aucune partie de cette publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit de l'éditeur. No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. Запрещается Без письменного разрешения издателя воспроизведение или копирование этой публикации или ее части в любой форме или любыми средствами — электронными или механическими, включая фотоконю и микрофильм. Bureau central de la Commission Electrotechnique Internationale 3, rue de Varembé Genève Suisse
|
50(715) © IEC:1996
CONTENTS
| FOREWORD | VII | |
| PREFACE | VII | |
| Sections | ||
| 715-01 | Basic terms | 1 |
| 715-02 | Resources | 10 |
| 715-03 | Calls | 17 |
| 715-04 | Times and delays | 22 |
| 715-05 | Traffic | 24 |
| 715-06 | Circuit groups | 32 |
| 715-07 | Traffic engineering | 34 |
| 715-08 | Networks | 41 |
| 715-09 | Circuit switched networks | 46 |
| 715-10 | Message switched networks | 51 |
| 715-11 | Packet switched networks | 52 |
| Index | 53 |
:current
Foreword
This document (EN 10216-3:2002) has been prepared by Technical Committee EC/TC 29, "Steel tubes and fittings for steel tubes", the secretariat of which is held by UNI.
This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by November 2002, and conflicting national standards shall be withdrawn at the latest by November 2002.
This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative annex ZA, which is an integral part of this document.
Other Parts of EN 10216 are:
| Part 1: | Non-alloy steel tubes with specified room temperature properties |
| Part 2: | Non-alloy and alloy steel tubes with specified elevated temperature properties |
| Part 4: | Non-alloy and alloy steel tubes with specified low temperature properties |
| Part 5: | Stainless steel tubes |
Another European Standard series covering tubes for pressure purposes is:
| EN 10217: | Welded steel tubes for pressure purposes |
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom.
5
1 Scope
This Part of EN 10216 specifies the technical delivery conditions in two test categories for seamless tubes of circular cross section, made of weldable alloyed fine grained steel.
2 Normative references
This European Standard incorporates by date or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For date references, subsequent amendments to or revisions of, any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies (including amendments).
The requirements of this European Standard rule when they differ from those in the standards and documents referred to below:
EN 10002-1, Metallic materials - Tensile testing - Part 1: Method of test (at ambient temperature).
EN 10002-5, Metallic materials - Tensile testing - Part 5: Method of testing (at elevated temperature).
EN 10020, Definitions and classification of grades of steel.
EN 10021, General technical delivery requirements for steel and iron products.
EN 10045-1, Metallic materials - Charpy impact test - Part 1: Test method.
EN 10052, Vocabulary of heat treatment terms for ferrous products.
EN 10204, Metallic products - Types of inspection documents.
EN 10027-1, Designation systems for steels - Part 1: Steel names, principle symbols.
EN 10027-2, Designation systems for steels Part 2: Numerical systems.
ENV 10220, Seamless and welded steel tubes - Dimensions and masses per unit length
EN 10233, Metallic materials - Tubes - Flattening test.
EN 10234, Metallic materials - Tubes - Drift expanding test.
EN 10236, Metallic materials - Tubes - Ring expanding test.
EN 10237, Metallic materials - Tubes - Ring tensile test.
EN 10246-1, Non-Destructive Testing of steel tubes Part 1: Automatic electromagnetic testing of seamless and welded (except submerged arc welded) ferromagnetic steel tubes for verification of hydraulic leak-tightness.
EN 10246-5, Non-Destructive Testing of steel tubes - Part 5: Automatic full peripheral magnetic transducer/flux leakage testing of seamless and welded (except submerged arc-welded) ferromagnetic steel tubes for the detection of longitudinal imperfections.
EN 10246-6, Non-Destructive Testing of steel tubes - Part 6: Automatic full peripheral ultrasonic testing of seamless steel tubes for the detection of transverse imperfections.
EN 10246-7, Non-Destructive Testing of steel tubes - Part 7: Automatic full peripheral ultrasonic testing of seamless and welded (except submerged arc welded) steel tubes for the detection of longitudinal imperfections.
6
预览内容由文件识别整理,表格、公式及文字请以原始文件为准。
原文图片预览
PAGE IMAGES下载标准文件
IEC 60099-5 A1 1999 surge arresters
英语 · PDF · 6 页 · 637.55 KB